Errata - Intel CORE 2 DUO E4000 - SPECIFICATION UPDATE 3-2008 Specification

Hide thumbs Also See for CORE 2 DUO E4000 - SPECIFICATION UPDATE 3-2008:
Table of Contents

Advertisement

Errata

Errata
AI1.
Writing the Local Vector Table (LVT) when an Interrupt is Pending
May Cause an Unexpected Interrupt
If a local interrupt is pending when the LVT entry is written, an interrupt may
Problem:
be taken on the new interrupt vector even if the mask bit is set.
Implication: An interrupt may immediately be generated with the new vector when a LVT
entry is written, even if the new LVT entry has the mask bit set.
no Interrupt Service Routine (ISR) set up for that vector the system will GP
fault.
If the ISR does not do an End of Interrupt (EOI) the bit for the vector
will be left set in the in-service register and mask all interrupts at the same
or lower priority.
Workaround: Any vector programmed into an LVT entry must have an ISR associated with
it, even if that vector was programmed as masked. This ISR routine must do
an EOI to clear any unexpected interrupts that may occur. The ISR associated
with the spurious vector does not generate an EOI, therefore the spurious
vector should not be used when writing the LVT.
For the steppings affected, see the Summary Tables of Changes.
Status:
AI2.
LOCK# Asserted During a Special Cycle Shutdown Transaction May
Unexpectedly De-assert
During a processor shutdown transaction, when LOCK# is asserted and if a
Problem:
DEFER# is received during a snoop phase and the Locked transaction is
pipelined on the front side bus (FSB), LOCK# may unexpectedly de-assert.
Implication: When this erratum occurs, the system may hang during shutdown. Intel has
not observed this erratum with any commercially available systems or
software.
Workaround: None identified.
For the steppings affected, see the Summary Tables of Changes.
Status:
AI3.
Address Reported by Machine-Check Architecture (MCA) on Single-bit
L2 ECC Errors May be Incorrect
When correctable Single-bit ECC errors occur in the L2 cache, the address is
Problem:
logged in the MCA address register (MCi_ADDR). Under some scenarios, the
address reported may be incorrect.
®
Intel
Core™2 Extreme Processor X6800 and
®
Intel
Core™2 Duo Desktop Processor E6000 and E4000 Sequence
Specification Update
If there is
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Core 2 duo e6000Core 2 extreme x6800