Removing An M120 Dc Power Supply; Figure 90: Disconnecting Power Cables From The M120 Dc Power Supply - Juniper M120 Hardware Manual

Multiservice edge router
Hide thumbs Also See for M120:
Table of Contents

Advertisement

M120 Multiservice Edge Router Hardware Guide
178

Removing an M120 DC Power Supply

The power supplies are located at the rear of the chassis to the right of the
power supply weighs approximately 8.4 lb (3.8 kg).
CAUTION: Do not leave a power supply slot empty for more than 30 minutes
while the router is operational. For proper airflow, the power supply must
remain in the chassis, or a blank panel must be used in an empty slot.
NOTE: After powering off a power supply, wait at least 60 seconds before
turning it back on.
To remove a DC power supply:
Make sure that the voltage across the DC power source cable leads is 0 V and that
1.
there is no chance that the cables might become active during the removal process.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
2.
the strap to one of the ESD points on the chassis.
Switch the circuit breaker on the power supply faceplate to the off position (
3.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
4.
Remove the nut and washer from the terminal studs (see Figure 90 on page 178). (Use
5.
a 3/8-in. nut driver or pliers.)

Figure 90: Disconnecting Power Cables from the M120 DC Power Supply

Remove the cable lugs from the terminal studs.
6.
Loosen the captive screws on the cable restraints on the lower edge of the power
7.
supply faceplate.
. Each
CB1
O
Copyright © 2010, Juniper Networks, Inc.
).

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents