C
ONFIGURING THE
Level
Severity Name
7
Debug
6
Informational
5
Notice
4
Warning
3
Error
2
Critical
1
Alert
0
Emergency
* There are only Level 2, 5 and 6 error messages for the current firmware release.
•
RAM Level – Limits log messages saved to the switch's temporary
RAM memory for all levels up to the specified level. For example, if
level 7 is specified, all messages from level 0 to level 7 will be logged to
RAM. (Range: 0-7, Default: 6)
Note: The Flash Level must be equal to or less than the RAM Level.
Web – Click System, Log, System Logs. Specify System Log Status, set the
level of event messages to be logged to RAM and flash memory, then click
Apply.
3-32
S
WITCH
Table 3-3. Logging Levels
Figure 3-15. System Logs
Description
Debugging messages
Informational messages only
Normal but significant condition, such as cold
start
Warning conditions (e.g., return false,
unexpected return)
Error conditions (e.g., invalid input, default used)
Critical conditions (e.g., memory allocation, or
free memory error - resource exhausted)
Immediate action needed
System unusable