Code
Text
E1711
PCI parity
error on #.
Review & clear
SEL.
E1712
PCI system
error on #.
Review & clear
SEL.
E1714
Unknown error.
Review & clear
SEL.
E171F
PCI fatal
error on #.
Review & clear
SEL.
E1810
Hard drive ##
fault. Review
& clear SEL.
E1812
Hard drive ##
removed.
Check drive.
Causes
The system BIOS has
reported a PCI parity
error on a component
that resides in PCI
configuration space at
bus ##, device ##,
function ##.
The system BIOS has
reported a PCI system
error on a component
that resides in PCI
configuration space at
bus ##, device ##,
function ##.
The system BIOS has
determined there has
been an error in the
system, but is unable to
determine its origin.
The system BIOS has
reported a PCIe fatal
error on a component
that resides in PCI
configuration space at
bus ##, device ##,
function ##.
The specified hard drive
has experienced a fault.
The specified hard
drive has been removed
from the system.
Corrective Actions
Remove and reseat the
PCIe expansion cards.
If the problem persists,
see "Troubleshooting
Expansion Cards" on
page 172.
Remove and reseat the
PCIe expansion cards.
If the problem persists,
see "Troubleshooting
Expansion Cards" on
page 172.
Check the SEL for
more information and
then clear the SEL.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 187.
Remove and reseat the
PCIe expansion cards.
If the problem persists,
see "Troubleshooting
Expansion Cards" on
page 172.
See "Troubleshooting a
Hard Drive" on page 169.
Information only.