Message
Thermal sensor
not detected
on x
Time-of-day
clock stopped
Time-of-day not
set - please run
SETUP program
Timer chip
counter 2 failed
TPM
configuration
operation
honored. System
will now reset.
TPM
configuration
operation is
pending. Press
(I) to Ignore
OR (M) to Modify
to allow this
change and reset
the system.
WARNING:
Modifying could
prevent
security.
TPM failure
50
About Your System
Causes
A memory module without a
thermal sensor is installed in
the specified memory slot.
Faulty battery or faulty chip. See "Troubleshooting the
Incorrect Time or Date
settings; faulty system
battery.
Faulty system board.
A TPM configuration
command has been entered.
The system reboots and
executes the command.
This message displays during
system restart after a TPM
configuration command has
been entered. User
interaction is required to
proceed.
A Trusted Platform Module
(TPM) function has failed.
Corrective Actions
Replace the memory
module. See "System
Memory" on page 104.
System Battery" on page 162.
Check the Time and Date
settings. See "Using the
System Setup Program and
UEFI Boot Manager" on
page 57. If the problem
persists, replace the system
battery. See "System Battery"
on page 133.
See "Getting Help" on
page 187.
Information only.
Enter I or M to proceed.
See "Getting Help" on
page 187.