Dell POWEREDGE R515 Hardware User Manual page 46

Dell computer hardware user manual
Hide thumbs Also See for DELL POWEREDGE R515:
Table of Contents

Advertisement

Message
Memory set to
minimum
frequency.
Memory tests
terminated by
keystroke.
MEMTEST lane
failure
detected on x
No boot device
available.
46
About Your System
Causes
The memory frequency may
be intentionally set lower for
power conservation.
The current memory
configuration may support
only the minimum frequency.
POST memory test was
terminated by pressing the
spacebar.
Invalid memory
configuration. Mismatched
memory modules are
installed.
Faulty or missing optical
drive subsystem, hard drive,
or hard drive subsystem, or
no bootable USB key
installed.
Corrective Actions
If not an intentional setting,
check any other system
messages for possible causes.
Ensure that your memory
configuration supports the
higher frequency.
See "General Memory
Module
Installation Guidelines" on
page 105.
Information only.
Ensure that the memory
modules are installed in a
valid configuration.
See "General Memory
Module
Installation Guidelines" on
page 105.
Use a bootable USB key,
optical drive, or hard drive.
If the problem persists,
see "Troubleshooting an
Optical Drive" on page 168,
"Troubleshooting a USB
Device" on page 158,
"Troubleshooting an Internal
USB Key" on page 167, and
"Troubleshooting a Hard
Drive" on page 169.
See "Using the System Setup
Program and
UEFI Boot Manager" on
page 57 for information on
setting the order of boot
devices.

Hide quick links:

Advertisement

Table of Contents
loading