Dell POWEREDGE R515 Hardware User Manual page 28

Dell computer hardware user manual
Hide thumbs Also See for DELL POWEREDGE R515:
Table of Contents

Advertisement

Code
Text
E1114
Ambient Temp
exceeds
allowed range.
E1116
Memory
disabled,
temp above
range.
Power
cycle AC.
E1210
Motherboard
battery
failure.
Check
battery.
E1211
RAID
Controller
battery
failure.
Check
battery.
E1216
3.3V Regulator
failure.
Reseat PCIe
cards.
E1229
CPU # VCORE
Regulator
failure.
Reseat CPU.
28
About Your System
Causes
Ambient temperature has
a reached a point outside
of the allowed range.
Memory has exceeded
allowable temperature and
has been disabled to
prevent damage to the
components.
CMOS battery is missing
or the voltage is outside of
the allowable range.
RAID battery is either
missing, bad, or unable
to recharge due
to thermal issues.
3.3 V voltage regulator
has failed.
Specified processor
VCORE voltage
regulator has failed.
Corrective Actions
See "Troubleshooting
System Cooling
Problems" on page 163.
Remove AC power to the
system for 10 seconds and
restart the system.
See "Troubleshooting
System Cooling
Problems" on page 163.
If the problem persists,
see "Getting Help" on
page 187.
See "Troubleshooting the
System Battery" on
page 162.
Reseat the RAID battery
connector. See "Installing
the RAID Battery" on
page 137, and
"Troubleshooting System
Cooling Problems" on
page 163.
Remove and reseat the
PCIe expansion cards.
If the problem persists,
see "Troubleshooting
Expansion Cards" on
page 172.
Reseat the processor(s).
See "Troubleshooting
Processors" on page 174.
If the problem persists,
see "Getting Help" on
page 187.