Code
Text
E1420
CPU Bus parity
error. Power
cycle AC.
E1422
CPU # machine
check error.
Power
cycle AC.
E1610

Power Supply #

(### W)
missing.
Check power
supply.
E1614
Power Supply #
(### W) error.
Check power
supply.
E1618
Predictive
failure on
Power Supply #
(### W).
Check PSU.
E161C
Power Supply #
(### W) lost
AC power.
Check PSU
cables.
Causes
The system BIOS has
reported a processor bus
parity error.
The system BIOS has
reported a machine
check error.
Specified power supply
was removed or is missing
from the system.
Specified power supply
has failed.
An over-temperature
condition or power supply
communication error has
caused the predictive
warning of an impending
power supply failure.
Specified power supply
is attached to the system,
but it has lost its
AC input.
Corrective Actions
Remove AC power to
the system for 10 seconds
and restart the system.
If the problem persists,
see "Getting Help" on
page 187.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 187.
See "Troubleshooting
Power Supplies" on
page 163.
See "Troubleshooting
Power Supplies" on
page 163.
See "Troubleshooting
Power Supplies" on
page 163.
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supplies" on page 163.