Cisco IAD2423-16FXS-RF - IAD 2423 Router System Message Manual page 84

Ethernet access switches
Table of Contents

Advertisement

SPANTREE Messages
error occurs because of an error in the platform-specific code, which causes it to request more or
less bits than are possible. The first [dec] is the number of bits for the port number, and the second
and third [dec] describe the valid range.
Recommended Action
Research and attempt to resolve the error by using the Output Interpreter. Enter the show version
user EXEC command to gather data that might help identify the nature of the error. Use the Bug
Toolkit to look for similar reported problems. If you still require assistance, open a case with the
TAC, or contact your Cisco technical support representative, and provide the representative with the
gathered information. For more information about these online tools and about contacting Cisco, see the
"Error Message Traceback Reports" section on page
Error Message SPANTREE-3-PORT_SELF_LOOPED: [chars] disabled.- received BPDU src mac
([enet]) same as that of interface.
Explanation
MAC address that matches the one assigned to the listed interface. This means that a port might be
looped back to itself, possibly because of an installed diagnostic cable. The interface will be
administratively shut down. [chars] is the interface that received the BPDU, and [enet] is the source
MAC address.
Recommended Action
When the problem is resolved, re-enable the interface by entering the no shutdown interface
configuration command.
Error Message SPANTREE-4-PORT_NOT_FORWARDING: [chars] [chars] [chars] [chars].
Explanation
[chars] is the mode (for example, assert or clear), and the second [chars] is the severity (for example,
minor). The third [chars] is the interface name, and the fourth [chars] is the alarm string (for
example, port not forwarding).
Recommended Action
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
Message Traceback Reports" section on page
Error Message SPANTREE-5-EXTENDED_SYSID: Extended SysId [chars] for type [chars].
Explanation
for the given type of spanning tree. If enabled, the spanning-tree instance identifier is stored in the
lower portion of the bridge ID priority field and limits the allowed values for the bridge priority from
0 to 61440, in increments of 4096. If disabled, the bridge ID priority field consists only of the
configured priority, but some spanning-tree features might not be available on a given platform (for
example, support for 4096 VLANs). On some platforms, this feature might be mandatory. The first
[chars] is the extended system ID state (enable or disable), and the second [chars] is the
spanning-tree instance.
Recommended Action
Cisco ME 3400E, ME 3400, and ME 2400 Ethernet Access Switch System Message Guide
2-72
Copy the message exactly as it appears on the console or in the system log.
This message means that a BPDU was received on the listed interface with a source
Check the interface configuration and any cable connected to the interface.
This message appears when a port-not-forwarding alarm is set or cleared. The first
Copy the message exactly as it appears on the console or in the system log.
This message means that the extended system ID feature is either enabled or disabled
No action is required.
Chapter 2
Messages and Recovery Procedures
1-3.
1-3.
"Error
OL-9641-04

Advertisement

Table of Contents
loading

This manual is also suitable for:

Me-2400-24ts-dMe 3400eMe 2400Me 3400 series

Table of Contents