Omron ZFX-C User Manual page 89

Vision sensor with built-in lcd monitor
Hide thumbs Also See for ZFX-C:
Table of Contents

Advertisement

Possible output results
The following values can be output when expressions are set.
Item
Judgment result
Edge angle
Edge position
Reference angle
Reference position
Angle difference
Position difference
For details on reference position, position difference p.50
86
Setting Measurement Items
Description
The judgment result is output. (0: OK, -1: NG, -2: not measured)
The measured angle is output. (-180 to 180)
The X, Y coordinates of the edge position are output. (-9999.999 to
9999.999)
The angle when the measurement region is set is output. (-180 to 180) Ref. angle (ST)
The X, Y coordinates of the edge position when the measurement
region is set are output. (-9999.999 to 9999.999)
The difference obtained by "measurement angle - reference angle " is
output. (-360 to 360)
The difference obtained by "measurement position - reference position"
is output. (-9999.999 to 9999.999)
Message
Judge (JG)
Angle (TH)
Position X, Y
(X, Y)
Reference X, Y
(SX, SY)
Angle dif. (DT)
Position dif. X, Y
(DX, DY)
ZFX-C User's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smart sensor zfx-c

Table of Contents