Setting Calibration by Specifying Points
With this method, calibration is set by specifying desired points (in pixel units). When the actual coordinates of
a specified position are input, the calibration data is automatically calculated.
When the scale in the X and Y directions is the same
When each of the scales in the X and Y directions are different
Setup method
MENU mode - [Setup] - [Cameras] - [Camera 0/1] - [Calibration] - [Specifying point]
Specifying point
Set 2 places.
Set 3 places.
Cameras
Register
X-Axis
7
4
1
0
Apply
110
Cameras/Lighting
Specify 2 locations and input the actual coordinates.
Specify 3 locations and input the actual coordinates.
SD
Position
Add func
Item
( 53, 60)
1st
Apply
Cancel
Y-Axis
80
0
8
9
AC
5
6
BS
2
3
.
+/-
Next
Cancel
1
Place the measurement target at the 1st point, and se-
lect either [Set 2 places.] or [Set 3 places.].
2
Move the crosshair cursor to the 1st point, and select
[Apply].
3
Input the actual coordinates of the 1st point.