Omron ZFX-C User Manual page 134

Vision sensor with built-in lcd monitor
Hide thumbs Also See for ZFX-C:
Table of Contents

Advertisement

Adjusting Logging Monitor Conditions
The logging monitor has the following three adjustment items.
Item
Description
Warning level
In addition to a judgment threshold, warning levels can be set so that a warning is dis-
played when the measurement result falls below or exceeds the warning value. Displaying
"Warning" before NGs frequently occur enables feedback to pre-processes.
Display range
The scale of the horizontal and vertical axes can be changed to make the graph easier-to-
(vertical axis)
view.
Number of display results
(horizontal axis)
Logging monitor/Data0
350
300
250
50
100
150
200
Data 276.000
Warning
Time 15:10:00
Log SW
Display SW
ZFX-C User's Manual
Logging monitor/Data0
350
300
250
50
100
Warning
Adjust
V-Axis
Warning level
Specify the warning level by ver-
tically dragging the bar or by di-
rectly entering numerical values.
350
300
250
150
200
L: 376.000
Return
H-Axis
Display range (vertical axis)
Specify the center value and scale
width using numerical values.
350
300
250
Center: 376.000
Number of display results (horizon-
tal axis)
Select from the currently displayed
options.
350
300
250
200
Checking/Adjusting the Measurement - ADJ Mode
Warning
50
100
150
200
H: 423.000
Apply
Capture
Cancel
V-Axis
50
100
150
200
Scale: 423.000
Apply
Cancel
Capture
H-Axis
50
100
150
200
1000 2000 4000 8000 10000
Apply
Cancel
Capture
131

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smart sensor zfx-c

Table of Contents