Omron ZFX-C User Manual page 69

Vision sensor with built-in lcd monitor
Hide thumbs Also See for ZFX-C:
Table of Contents

Advertisement

Possible output results
The following values can be output when expressions are set.
Item
Judgment result
Area
Gravity position
Axis angle
Reference area
Reference position
Reference axis angle
Area difference
Position difference
Axis angle difference
For details on reference position, Position difference p.50
66
Setting Measurement Items
Description
The judgment result is output. (0:OK, -1:NG, -2: not measured)
The area of the measurement target color is output.
(0 to 9999999.999)
The X, Y coordinates of the gravity of the measurement target color
are output. (-9999.999 to 9999.999)
The angle of the measurement target color is output.
(-90.0 to 90.0)
The area when the measurement region is set is output.
(0 to 9999999.999)
The X, Y coordinates of the gravity when the measurement region is
set are output. (-9999.999 to 9999.999)
The angle when the measurement region is set is output.
(-90.0 to 90.0)
The area difference obtained by "measurement value - reference
value" is output. (-9999999.999 to 9999999.999)
The position difference obtained by "gravity position - reference
position" is output. (-9999.999 to 9999.999)
The axis angle difference obtained by "measurement value -
reference value" is output. (-180.0 to 180.0)
Message
Judge (JG)
Area (AR)
Gravity X, Y
(X, Y)
Axis angle (TH)
Ref. area (SA)
Reference X, Y
(SX, SY)
Ref. axis angle
(ST)
Area dif. (DA)
Position dif. X, Y
(DX, DY)
Axis angle dif.
(DT)