Omron ZFX-C User Manual page 71

Vision sensor with built-in lcd monitor
Hide thumbs Also See for ZFX-C:
Table of Contents

Advertisement

Threshold
This function sets the judgment conditions.
Judgment is performed on corresponding label Nos.
MENU mode - [Setup] - [Item] - [Limits]
Setup Item
Area
Gravity XY
Number of labels
Axis angle
Perimeter
Length XY
Roundness
Detailed settings (if necessary)
When measurement is not stable, adjust the detailed conditions.
MENU mode - [Setup] - [Item] - [Detail]
Setup Item
Labeling mode
Sort mode
Label No.
Measure axis angle
68
Setting Measurement Items
Description
Sets the range of the area to be judged as OK.
Range: 0 to 9999999.999 (When calibration is OFF, the range of the area becomes 0 to
307200.)
Sets the range of movement in the X- and Y-axes of the measurement target to be judged
as OK.
Range: -9999.999 to 9999.999 (When calibration is OFF, the range of movement for posi-
tions X and Y are 0 to 640 and 0 to 480, respectively.)
Sets the number of labels of the measurement target to be judged as OK.
Range: 0 to 65535
Sets the rotating range of the measurement target to be judged as OK.
Range: -90.0 to 90.0
+/- direction of angle
Sets the perimeter of the measurement target to be judged as OK.
Range: 0 to 9999999.999 (When calibration is OFF, the range of the perimeter becomes 0
to 200000.)
Sets the X and Y lengths of the box circumscribing the measurement target to be judged
as OK.
Range: -9999.999 to 9999.999 (When calibration is OFF, the range of movement for posi-
tions X and Y are 0 to 640 and 0 to 480, respectively.)
Sets the roundness of the measurement target to be judged as OK.
Range: 0 to 1.0
Setting value
Precision
Normal (default value)
Area descending order
(default value)
Area ascending order
X gravity descending order Re-assigns label Nos. in order of the largest X gravity coordinate.
X gravity ascending order
Y gravity descending order Re-assigns label Nos. in order of the largest Y gravity coordinate.
Y gravity descending order Re-assigns label Nos. in order of the smallest Y gravity coordinate.
0 to 2499 (default value: 0) Sets the label No. whose data is to be output.
OFF (default value)
ON
p.64
Description
The image is measured without being compressed.
The image is measured at high speed after being compressed
to 1/2 size in both the horizontal and vertical directions.
Re-assigns label Nos. in order of the largest area.
Re-assigns label Nos. in order of the smallest area.
Re-assigns label Nos. in order of the smallest X gravity coordinate.
When set to "ON", the axis angle is calculated.
ZFX-C User's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smart sensor zfx-c

Table of Contents