Possible output results
The following values can be output when expressions are set.
Item
Judgment result
Area
Gravity position
Number of labels
Axis angle
Perimeter
Length XY
Roundness
Reference area
Reference position
Reference axis angle
Reference perimeter
Reference length XY
Reference roundness
Area difference
Position difference
Axis angle difference
Perimeter difference
Length XY difference
Roundness difference
Reference position and position difference
70
Setting Measurement Items
Description
The judgment result is output. (0: OK, -1: NG, -2: not measured)
The area of the corresponding label is output. (0 to 9999999.999)
The X, Y coordinates of the gravity of the corresponding label are out-
put. (-9999.999 to 9999.999)
The total number of labels is output. (0 to 65535)
The angle of the corresponding label is output. (-90.0 to 90.0)
The perimeter of the corresponding label is output. (0 to 9999999.999)
The X and Y lengths of the box circumscribing the corresponding
label are output. (0 to 9999.999)
The roundness of the corresponding label is output. (0 to 1.0)
The area of the corresponding label when the measurement region is
set is output. (0 to 9999999.999)
The X, Y coordinates of the gravity of the corresponding label when
the measurement region is set are output. (-9999.999 to 9999.999)
The angle of the corresponding label when the measurement region
is set are output. (-90.0 to 90.0)
The perimeter of the corresponding label when the measurement
region is set is output. (0 to 9999999.999)
The X and Y lengths of the box circumscribing the corresponding
label when the measurement region is set are output. (0 to 9999.999)
The roundness of the corresponding label when the measurement
region is set is output. (0 to 1.0)
The area difference obtained by "measurement value - reference
value" is output. (-9999999.999 to 9999999.999)
The position difference obtained by "gravity position - reference posi-
tion" is output. (-9999.999 to 9999.999)
The axis angle difference obtained by "measurement value - refer-
ence value" is output. (-180.0 to 180.0)
The perimeter difference obtained by "measurement value - reference
value" is output. (-9999999.999 to 9999999.999)
The length difference obtained by "measurement value - reference
value" is output. (-9999.999 to 9999.999)
The roundness difference obtained by "measurement value - refer-
ence value" is output. (-1.0 to 1.0)
p.50
Message
Judge (JG)
Area (AR)
Gravity X, Y (X, Y)
Number of labels (N)
Axis angle (TH)
Perimeter (L)
Length X, Y
(LX, LY)
Roundness (CL)
Ref. area (SA)
Reference X, Y
(SX, SY)
Ref. axis angle
(ST)
Ref. perimeter
(SL)
Ref. length X, Y
(SLX, SLY)
Ref. roundness
(SC)
Diff. area (DA)
Displacement X, Y
(DX, DY)
Diff. axis angle
(DT)
Diff. perimeter
(DL)
Diff. length X, Y
(DLX, DLY)
Diff. roundness
(DC)