Operating Data Area Monitoring
3. Select either Automatic or Manual to start monitoring. Automatic continues
monitoring until the Stop Monitor Button is clicked. Manual refreshes the
monitor screen contents.
Data
Positions
Speeds
Acceleration
times
Deceleration
times
Sequence num-
bers
Overrides
Teaching
addresses
Not used
Present posi-
tions
Sequence num-
bers
Output codes
Note
1. The first word address depends on the setting in words m and m+1 of the
common parameters (where m = D20000 + 100 × unit number) Refer to the
Operation Manual for the NC Unit for details.
2. Refer to the Operation Manual for the NC Unit for details on operating data
area.
Allocated words (See note 1.)
NC1
3
NC2
3
@
@
X axis
X axis
Y axis
l+8
l+8
l+20
l+9
l+9
l+21
l+10
l+10
l+22
l+11
l+11
l+23
l+12
l+12
l+24
l+13
l+13
l+25
l+14
l+14
l+26
l+15
l+15
l+27
l+16
l+16
l+28
l+17
l+17
l+29
l+18
l+18
l+30
l+19
l+19
l+31
l+20
l+32
l+36
l+21
l+33
l+37
l+22
l+34
l+38
l+23
l+35
l+39
Section 8-4
NC4
3
@
X axis
Y axis
Z axis
l+8
l+20
l+32
l+9
l+21
l+33
l+10
l+22
l+34
l+11
l+23
l+35
l+12
l+24
l+36
l+13
l+25
l+37
l+14
l+26
l+38
l+15
l+27
l+39
l+16
l+28
l+40
l+17
l+29
l+41
l+18
l+30
l+42
l+19
l+31
l+43
l+56
l+60
l+64
l+57
l+61
l+65
l+58
l+62
l+66
l+59
l+63
l+67
U axis
l+44
l+45
l+46
l+47
l+48
l+49
l+50
l+51
l+52
l+53
l+54
l+55
l+68
l+69
l+70
l+71
85