NC Unit Error Logs
Group
Name
Intelligent
IORD format
Read/Write
error
IOWR format
error
Flash
Flash mem-
memory
ory error
Code
Cause
8700
One of the following errors
occurred when the IORD instruc-
tion was executed:
The NC Unit's address was out-
side the settable range.
8701
One of the following errors
occurred when the IOWR instruc-
tion was executed:
The NC Unit's address was out-
side the settable range.
The parameters for the origin
search high speed and the origin
search proximity speed were not
sent together.
9300
An attempt was made to save
data to flash memory, but the data
couldn't be saved because of a
problem with the flash memory.
Clearing method
Execute the instruc-
tion again after correct-
ing the data.
Execute the data save
operation again. The
error will be cleared if
the data is written nor-
mally. Replace the Unit
if the error occurs
again.
(In some cases the
data save operation
can take up to 30 s.)
Section 10-1
Operation after error
The current data trans-
fer will not be exe-
cuted, but other
operating axes will not
be affected.
The current instruc-
tion will not be exe-
cuted.
All axes will be decel-
erated to a stop.