Set-up the GRT1-PNT Configuration
3-4-2
Set-up using the DTM
PROFINET IO tab
I/O Module Tab
GRT1-PNT DTM window which pops up after double-clicking the GRT1-PNT
entry in the Network View is shown below.
The window has two tab pages: one for the settings of the PROFINET IO
Communication unit itself and one for defining connected I/O Modules.
Note
The buttons on the bottom will be enabled only when the DTM is on-line
Comment
The comment field contains comments or descriptions of the station.
Name of Station
This field contains the name of the station, by which it is known to the IO
Controller.
IP settings
This sections contains the IP address, network mask and gateway address.
These address are assigned by the IO Controller and cannot be changed
here.
The I/O Module tab, shown below, defines the I/O Configuration for the GRT1-
PNT. This I/O Configuration is downloaded to the PROFINET IO
Communication Unit and sent to the physical device by the Communication
Unit for verification at the start of communication.
Section 3-4
.
55