Power Supply Led; Firmware And Rot Security Module Leds - Lenovo ThinkSystem SD530 V3 User Manual

Hide thumbs Also See for ThinkSystem SD530 V3:
Table of Contents

Advertisement

Power supply LED

This topic provides information about various power supply LED status and corresponding action
suggestions.
• The following minimal configuration is required for the node to start:
– One processor in socket 1
– One memory module in DIMM slot 4
– One power supply in PSU slot 1
– One boot drive, M.2 or E3.S drive, and RAID adapter if configured (If OS is needed by debugging)
– Four system fans
The following table describes the problems that are indicated by various combinations of the power-supply
LED and the power-on LED and suggested actions to correct the detected problems.
Figure 146. Power supply LED
Description
LED
The power supply status LED can be in one of the following states:
• Green: The power supply is connected to the AC power source and working normally.
• Off: The power supply is disconnected from the AC power source.
• Slow blinking green (about one flash every second): The power supply is in PSU standby
Power supply
1
state with AC present, cold standby state, or always standby state.
status
• Amber: The AC power cord is unplugged, AC power lost (with a second power supply in
parallel still in AC power input power), or power supply has failed. To resolve the issue, replace
the power supply.
• Slow blinking amber (about one flash every second): Power supply warning events where
the power supply continues to operate.

Firmware and RoT security module LEDs