5 STATE VARIABLE

5. STATE VARIABLE
States variable for the safety monitoring function are shown below:

5.1 List of State Variables

5.2 State Variables

M_DSI
[Function]
Regarding DSI for functional safety, this refers to the current value.
DSI Input enabled: 1
DSI Input disabled: 0
[Format]
Example) <Numerical variable> = M_DSI( <DSI number> )
[Terminology]
<Numerical variable> This specifies where to store the DSI state.
<DSI number> This specifies a number for DSI whose state to be obtained.
Setting range: 1 to 8
[Reference Program]
M1 = M_DSI(1)
'The state of DSI1 is stored in M1.
[Explanation]
(1) Regarding DSI for functional safety, this refers to the current state.
(2) The value changes after the DSI filer setting time elapses following change in the input signals DSIn_A and
DSIn_B.
(3) Assigning a value other than 1 to 8 to <DSI number> causes the L.3880 error on execution.
5-88 List of State Variables
Tab. 5-1: List of state variables
State variable
M_DSI
M_SfILogic
M_SfIArea
M_SfSts
M_DSO
M_SlpPreStp
Overview
Refers to the DSI Input state.
Refers to the Logic Input state.
Refers to the Area Input state.
Refers to the running state of the
safety monitoring.
Refers to the DSO output state.
Refers to the SLP pre-stop status