Roughing-In: K-1200-Ac, K-1201-Ac; Ordering Information; Required Electrical Service; Product Information - Kohler K-1200-AC Installation Instructions Manual

Builder portfolio whirlpool baths
Table of Contents

Advertisement

1. ROUGHING-IN: K-1200-AC, K-1201-AC

A. ORDERING INFORMATION
Factory installed components include pump and air switch
transmitter.
Information contained in this roughing-in also applies to
K-1201-J1-AA, K-1201-J1-AB and K-1201-JA-AA.
Whirlpool with wall timer
Whirlpool with air actuator (shown)
Accessories/hardware:
Drain
Vinyl tiling-in bead*
*Use K-1177 vinyl bead when wall material contacts any
top surface of bath.
B. REQUIRED ELECTRICAL SERVICE
Dedicated circuits required, protected with Class A
Ground-Fault Circuit-Interrupter (GFCI):
Pump/control
120 V., 15 A, 60 Hz
FIELD WIRING COMPARTMENT
15"
1-1/2"
8-1/2"
60"
2-3/4"
2-7/8"
3"
1.25>132
Kohler Co., Kohler WI
K-1200-AC
K-1201-AC
K-7161-AF recom-
mended
K-1177
optional
PUMP
1-1/2"
17"
É
3/16"
1-1/2" I.P.S. THR'D
C. PRODUCT INFORMATION
Fixture:
basin area
Bathing well
42" x 17"
water depth
To overflow
12-1/8"
Pump:
hp
60 Hz
1/2
D. INSTALLATION NOTES
Refer to installation instructions included with fixture before
beginning installation.
ROUGHING-IN NOTES
Fixture dimensions are nominal and conform to toler-
ances in ANSI Standard Z124.1.
No change in measurements if connected with drain
illustrated.
Cut-out
Minimum access:
Pump/control box 20" W x 15" H panel required
PUMP/CONTROL ACCESS
30"
1-1/2" O.D.
5
top area
weight
55" x 25"
93 lbs.
capacity
50 gals.
V
Hz
120
60
28-1/2" x 58-1/2"
CA
106548-
(9437)
A
8

Advertisement

Table of Contents
loading

Table of Contents