Roughing-In: K-1201; Ordering Information; Required Electrical Service; Product Information - Kohler Hourglass 30 K-1201 Installation Instructions Manual

Table of Contents

Advertisement

1. ROUGHING-IN: K-1201, HOURGLASS 30
A. ORDERING INFORMATION
Accessories/hardware:
Jet trim kit
Apron
Drain
Vinyl tiling-in bead*
*Use K-1177 vinyl bead when wall material contacts any
top surface of bath.
B. REQUIRED ELECTRICAL SERVICE
Dedicated branch circuit required, protected with Class A
Ground-Fault Circuit-Interrupter (GFCI):
Pump/control
120 V, 15 A, 60 Hz
15"
1-1/2"
8-1/2"
2-3/4"
EA
113867-2-
(-)
K-9694
included
K-1279
optional
K-7161-AF recommended
K-1177
optional
60"
2-7/8"
3/16"
3"
C. PRODUCT INFORMATION
Fixture*:
basin area
Bathing well
42" x 17"
water depth
To overflow
12-1/8"
* Approximate measurements for comparison only.
Pump:
HP
1-speed
3/4
D. INSTALLATION NOTES
Read the entire installation instruction before beginning the
installation.
Pump is supplied with a grounding-type plug-in cord. Locate
the outlet behind the whirlpool, and within 24" of the pump.
The optional apron must be installed before the finish floor
and wall materials are installed.
ROUGHING-IN NOTES
Fixture conforms to ANSI Standard Z124.1. All
dimensions are nominal.
No change in measurements if connected with drain il-
lustrated.
Cut-out
58-1/2" x 28-1/2"
Minimum access panel:
Pump/control
20" W x 15" H
PUMP/CONTROL ACCESS
30"
1-1/2"
17"
15-1/2"
1-1/2" O.D.
4
top area
weight
55" x 25"
93 lbs.
capacity
50 gal.
V
Hz
A
120
60
10.5
required
Kohler Co., Kohler WI