6
A new project "New1|AZ
EtherNet/IP compatible :
Standard/Geared Motor" opens.
Click (p12) Communication &
I/F by scrolling down the list
displayed under Parameter.
7
The (p12) Communication_I/F
Tab Page is displayed.
Scroll down the parameter list to
display 12 Configuration Control
(attr.3) and subsequent
parameters.
Check that the values of the
parameters from 14 IP Address
1 to 17 IP Address 4 are 192,
168, 1 and 1 (default),
respectively.
Check that the values of the
parameters from 18 Network
Mask 1 to 21 Network Mask 4
are 255, 255, 255 and 0
(default), respectively.
*If not, change to the default
values.
8
Change the value of 12
Configuration Control (attr.3) to
Parameter by selecting from
the pull-down list.
*The IP address can be set with
the parameters.
7.EtherNet/IP Connection Procedure