Removal And Replacement Of Parts; Covers And Panels; Oven Manifold Cover (Models 60, 260, And 481); Oven Control Panel (Model 36) - Vulcan-Hart G260 Service Manual

Endurance series gas ranges
Table of Contents

Advertisement

ENDURANCE SERIES GAS RANGES - REMOVAL AND REPLACEMENT OF PARTS

REMOVAL AND REPLACEMENT OF PARTS

COVERS AND PANELS

WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.

Oven Manifold Cover (Models 60, 260, and 481)

1.
Rotate the yellow gas shut-off valve to the OFF
position and allow range to cool.
2.
Loosen the setscrew in the side of the burner
control knobs and oven control knob and remove
knobs.
F35425 (October 2005)
3.
Remove screws holding manifold cover in place
and remove manifold cover.
4.
Reverse the procedure to install the oven
manifold cover.

Oven Control Panel (Model 36)

1.
Rotate the yellow gas shut-off valve to the OFF
position and allow range to cool.
2.
Remove the red oven control valve knob from
the control valve.
3.
Open the kick plate at the bottom of the range.