Standard Oven & Griddle Thermostat Replacement - Vulcan-Hart EG160 Service Manual

Gas restaurant range
Table of Contents

Advertisement

STANDARD OVEN & GRIDDLE THERMOSTAT REPLACEMENT
STANDARD OVEN AND GRIDDLE THERMOSTAT CHECKS AND CALIBRATION
Refer to THERMOSTAT ADJUSTMENTS on Page 18 of this manual for the procedures for checking and calibrating the
thermostat for the standard oven and griddle.
STANDARD OVEN AND GRIDDLE THERMOSTAT REPLACEMENT
TOOLS REQUIRED: Pipe wrench, 6" adjustable wrench,
1. Disconnect unit gas supply and allow unit to cool.
2. From inside the oven cavity, remove the capillary bulb from the clips mounted to the cavity back wall (Fig. 28).
3. Remove the top grates or griddle sections required to access the thermostat and capillary wiring (Fig. 29).
Fig. 28
1
" flat blade screwdriver,
8
– 25 –
5
" socket, and socket wrench.
16
Fig. 29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eg260Eg48Eg36Eg60Eg24