Convection Oven Control Valve/Thermocouple Pilot - Vulcan-Hart G260 Service Manual

Endurance series gas ranges
Table of Contents

Advertisement

ENDURANCE SERIES GAS RANGES - REMOVAL AND REPLACEMENT OF PARTS
2.
Remove the two screws securing the oven
burner assembly.
3.
Disconnect gas line to the burner.
4.
Pull the oven burner assembly out of the oven.
5.
Reverse the procedure to install a new oven
burner assembly.
CONVECTION OVEN CONTROL
VALVE/THERMOCOUPLE PILOT
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
WARNING: SHUT OFF THE GAS BEFORE
SERVICING THE UNIT.
WARNING: ALL GAS JOINTS DISTURBED
DURING SERVICING MUST BE CHECKED FOR
LEAKS. CHECK WITH A SOAP AND WATER
SOLUTION (BUBBLES). DO NOT USE AN
OPEN FLAME.
The control valve is located behind the oven manifold
cover.
1.
Remove the oven manifold cover as outlined
under COVERS AND PANELS.
2.
Remove top burner grates and deflector,
if necessary, to access the control valve.
3.
Disconnect the pilot tubing.
4.
Remove the two screws securing the control
valve to the manifold.
5.
Remove the kick plate as outlined under
COVERS AND PANELS.
NOTE: Do not kink the capillary tube when straight-
ening the tubing for removal.
6.
Slide the capillary tube and thermocouple out of
the bracket and straighten the tube so that it can
be passed through the holes in the oven liner.
7.
Remove the capillary tube from all routing clips.
8.
Carefully slide the capillary tube and
thermocouple through the holes in the oven.
9.
Remove the control valve, capillary tube and
thermocouple from the unit.
10. Reverse the procedure to install a new control
valve assembly.
NOTE: During installation do not kink the new
capillary tube when feeding it through the holes in the
oven. Excess tubing can be loosely wrapped.
Page 9 of 23
F35425 (October 2005)

Advertisement

Table of Contents
loading

This manual is also suitable for:

G36G260cG36cG481G481cG60 ... Show all

Table of Contents