Canon NP-1010 Service Manual page 62

Table of Contents

Advertisement

;.-
IV.
EXPOSURE
SYSTEM
A.
Lamp Unit
1.
Removing
the Scanning
Lamp
I) Disconnect the power plug.
2)
Remove the upper rear cover, upper front
cover,
upper
left cover,
and
upper
right
cover in the order named, and remove the
copyboard
glass.
3)
Hold the rear of the mirror 1 mount, and
move it to the right until it comes to the
cut shown in Figure 4-24.
Note:
Be sure to hold the mirror 1 mount as shown
in Figure 4-22;
the reflector deforms easily.
@
Mirror 1 mount
Figure 4-22
4)
Remove
the
screw
from
the
electrode
mount (rear).
@
Screw
@
Electrode mount (rear)
Figure 4-23
5)
Remove
the
screw
from
the
electrode
mount (front).
'^
i
@
Electrode mount (front)'
@
Cut
@
Screws
Figure 4-24
6)
Lift the front of the mirror
1 mount,
re-
move the electrode
mount (front) at A and
then
B, and pull out the scanning
lamp
slowly.
@
Electrode mount (front)
@
Scanning lamp
Figure 4-25
Note:
When
mounting the scanning lamp, hold it so
that its boss faces down at an angle.
COPVAIGHT
@l&W
CANON INC.
CANON HP-1010
AN.0
DEC. 1988 PRINTtO
IN JAFIN
lIMPRIME
AU JAPONI
4-9