CYBEX 525T Service Manual page 88

Hide thumbs Also See for 525T:
Table of Contents

Advertisement

Cybex 525T Treadmill Part Number
Error 95: Low Voltage (DC Link)
Cause:
Input voltage drops to unacceptable limits:
• <200V for the 230V unit
• <85V for the 115V unit
Service:
Error 95 is caused by a power outage while the belt is moving, either on purpose (running the treadmill
to incline it, then shutting it off with the power switch) or by an outside influence (plug was kicked, loose
fitting outlet, power outage, circuit breaker tripped, or simply shutting of the power at the breaker).
• Verify the input voltage is correct for the controller used.
• Monitor input voltage for brown-outs and sags.
• Make sure the treadmill is on a dedicated circuit.
More than likely, power was interrupted during use and the treadmill itself has nothing wrong with it.
Page 88 of 199

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents