GEM R488 Victoria Operating Instructions Manual page 42

Motorized butterfly valve
Hide thumbs Also See for R488 Victoria:
Table of Contents

Advertisement

Available languages

Available languages

9 Abmessungen
Anschluss AS 2129, BS10
DN
INCH
AS 2129 D (Code T)
DIN
ANSI
50
2"
90
4
65
2½"
90
4
80
3"
90
4
100
4"
90
4
125
5"
45
8
150
6"
45
8
200
8"
45
8
250
10"
45
8
300
12"
30
12
350
14"
30
12
Maße in mm
n = Anzahl der Schrauben
GEMÜ R488 Victoria
AS 2129 E (Code U)
n
ØG
y
114,0
M16
90
127,0
M16
90
146,0
M16
90
178,0
M16
45
210,0
M16
45
235,0
M16
45
292,0
M16
45
356,0
M20
30
406,0
M20
30
470,0
M22
30
Anschluss (Code)
n
ØG
y
4
114,0
M16
90
4
127,0
M16
90
4
146,0
M16
90
8
178,0
M16
90
8
210,0
M16
45
8
235,0
M20
45
8
292,0
M20
45
12
356,0
M20
45
12
406,0
M22
30
12
470,0
M27
30
42 / 172
BS10 D (Code H)
n
ØG
y
4
114,0
M16
90
4
127,0
M16
90
4
146,0
M16
90
4
178,0
M16
45
8
210,0
M16
45
8
235,0
M16
45
8
292,0
M16
45
8
356,0
M20
30
12
406,0
M20
30
12
470,0
M22
30
BS10 E (Code S)
n
ØG
y
4
114,0
M16
4
127,0
M16
4
146,0
M16
8
178,0
M16
8
210,0
M16
8
235,0
M20
8
292,0
M20
12
356,0
M20
12
406,0
M22
12
470,0
M27
www.gemu-group.com