7 Technische Daten Absperrklappe

7.5 Mechanische Daten

Drehmomente:
Anzugsdrehmomente:
GEMÜ R488 Victoria
DN
25
40
50
65
80
100
125
150
200
250
300
350
400
450
500
600
Drehmomente in Nm
* Standard
Betriebsmedium Wasser (20 °C) und optimalen Betriebsbedingungen
Schraubengröße
M5
M6
M8
M10
M12
M14
M16
M20
M24
3 bar
6 bar
-
-
-
-
3,0
5,0
8,0
10,0
10,0
15,0
15,0
20,0
25,0
35,0
40,0
50,0
100,0
-
140,0
-
200,0
-
255,0
-
580,0
-
600,0
-
860,0
-
1441,0
-
5 – 6
10 – 11
23 – 25
48 – 52
82 – 86
132 – 138
200 – 210
390 – 410
675 – 705
24 / 172
PS
10 bar
-
-
7,0
13,0
20,0
30,0
45,0
80,0
-
200,0
300,0
430,0
1035,0
1150,0
1250,0
2140,0
Anzugsdrehmoment [Nm]
www.gemu-group.com
16 bar *
4,0
7,0
9,0
15,0
25,0
40,0
60,0
100,0
160,0
-
-
-
-
-
-
-