Model Specifications (Three-Phase 400 V Class) - YASKAWA LA500 Technical Manual

Ac micro drive
Table of Contents

Advertisement

10.2

Model Specifications (Three-Phase 400 V Class)

Model
Duty Rating
Maximum Applicable Motor
*1
Output
(kW)
Maximum Applicable Motor
*1
Output
(HP)
Rated Input
Input
Current (A)
Rated Output
*2
Capacity
(kVA)
Rated Output
Current (A)
Overload Tolerance
Output
Carrier Frequency
Maximum Output Voltage
Maximum Output Frequency
Measures for
DC reactor
Harmonics
Braking Device Braking Transistor
EMC Filter
EMC Filter
IEC61800-3
Rated Voltage/Rated Frequency
Permitted Voltage Fluctuation
Power supply
Permitted Frequency Fluctuation
Input Power
(kVA)
*1
The maximum applicable motor output complies with 380 V motor ratings as specified in Annex G of IEC 60947-4-1. The rated
output current of the drive output amps must be equal to or more than the motor rated current.
*2
The rated output capacity is calculated with a rated output voltage of 440 V.
YASKAWA SIEPYEULA5001C LA500 Technical Manual
Table 10.2 Ratings (Three-Phase 400 V Class)
4009
4015
HD
4.0
5.5
HD
5
10
HD
10.4
15
HD
7
11.3
HD
9.2
14.8
• HD: 150% of the rated output current for 60 seconds, or 165% for 30 seconds. The permitted frequency of overload is
one time each 10 minutes.
HD: 8 kHz without derating the drive capacity.
Derate the drive capacity to use values to 15 kHz maximum.
Three-phase 380 V to 480 V
Note:
The maximum output voltage is proportional to the input voltage.
• V/f, OLV: 120 Hz
External options
Standard internal characteristics
Factory option
Models 4xxxE: Category C2 (Conducted emission)
Three-phase AC power supply 380 V to 480 V at 50/60 Hz
-15% to +10%
±5%
HD
9.5
14

10.2 Model Specifications (Three-Phase 400 V Class)

4018
4024
7.5
11.0
10
15
20
29
13.7
18.3
18.0
24.0
18
27
4031
4039
4045
15.0
18.5
22.0
20
25
30
39
50.5
59.7
23.6
29.7
34.3
31.0
39.0
45.0
36
47
55