9
|
Electrical installation
9.2.3 To reposition the air thermistor on the outdoor unit
Installer reference guide
118
This procedure is only necessary in areas with low ambient temperatures.
Required accessory (delivered with the unit):
Thermistor fixture.
2
4
6
3
5
Click
7
ERRA08~12E + ELVZ12S18+23E
Daikin Altherma 3 R MT F
4P708478-1 – 2023.05