3.3

Normal Usage Guidelines

Normal use of the display is defined as operating in the open air to prevent heat buildup, and
without direct or indirect heat sources such as lighting fixtures, heating ducts, or direct sunlight
that can cause the displays to experience high operating temperatures. For all displays, do not
block fans or ventilation openings. If the display will be installed in a recessed area with an
enclosure, ensure adequate openings are applied for proper air flow and ventilation.
It is up to the installer to ensure that display placement is changed, thermal shielding is provided
and/or additional ventilation is provided to keep the display within its nominal operating
parameters. Maximum ambient operating temperatures for the Planar UltraRes L Series are:
0-40°C at up to 1000 meters
0-35°C at up to 2000 meters
0-30°C at up to 3000 meters
Cooling Requirements
For optimal performance, active cooling by the installer should be planned for when the ambient
temperature anywhere in the wall is predicted to be above the specified ambient temperature for
the display.
Planar UltraRes L Series User Manual
020-1427-00A
11
Page | 11