Planar UltraRes P Series User Manual

Planar UltraRes P Series User Manual

Hide thumbs Also See for UltraRes P Series:
Table of Contents

Advertisement

Quick Links

Planar
Planar UltraRes P Series User Manual
020-1407-01B
User Manual
®
UltraRes
TM
P Series
URP49 | URP49-T
URP55 | URP55-T
URP65 | URP65-T
URP75 | URP75-ERO-T
URP85 | URP85-ERO-T
Page | 1

Advertisement

Table of Contents
loading

Summary of Contents for Planar UltraRes P Series

  • Page 1 User Manual ® Planar UltraRes P Series URP49 | URP49-T URP55 | URP55-T URP65 | URP65-T URP75 | URP75-ERO-T URP85 | URP85-ERO-T Planar UltraRes P Series User Manual Page | 1 020-1407-01B...
  • Page 2 When you purchase a Planar product, you get more than a display; you get the service and support you need to maximize your investment. To find the latest warranty and service information regarding your Planar product, please visit http://www.planar.com/support...
  • Page 3: Table Of Contents

    ENERGY STAR Certified ................. 11 Cleaning the Display ......................12 Unpacking and Checking Accessories..............13 Package Contents ......................13 Accessory Kit ........................13 Planar UltraRes P Series – Standard Inputs ..............16 URP49 / URP49-T ...................16 URP55 / URP55-T ...................17 URP65 / URP65-T ...................18 URP75 / URP75-ERO-T ...................19 URP85 / URP85-ERO-T ...................20...
  • Page 4 Remote Monitoring Panel Brightness and Power .............81 Remote Monitoring Notifications ..................82 Remote Monitoring System Settings ................84 Remote Monitoring Access Control ..................85 Planar UltraRes P Series URP49 / URP55 / URP65 Remote Monitoring Software . 86 Login ..........................86 Information ........................87 Network ...........................87 SMTP ..........................88...
  • Page 5 Symptom: Can’t Get PC to Output 4K @ 24/30/60 Hz........118 45.3 Symptom: IR Isn’t Working Properly ............... 118 45.4 45.5 Symptom: Touch Has Broken Response Near Middle/Bottom of Display ..119 Accessing Planar’s Technical Support Website ............. 120 Planar UltraRes P Series User Manual Page | 5 020-1407-01B...
  • Page 6: Introduction

    Introduction The Planar® UltraRes™ P Series is a line of 49", 55", 65", 75" and 85" 4K resolution (3840 x 2160) professional LCD displays with 500-nit brightness. The displays offer superior visual performance with multi-source viewing and advanced processing ideal for applications ranging from collaborative meeting spaces to high-impact digital signage and media rooms.
  • Page 7: Safety Information

    Safety Information Before using the Planar UltraRes P Series, please read this manual thoroughly to help protect against damage to property, and to ensure personnel safety. • Be sure to observe the following instructions. • For your safety, be sure to observe ALL the warnings detailed in this manual.
  • Page 8: Important Safety Instructions

    9. Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles and the point where they exit from any Planar large format LCD display. 10. Only use the attachments/accessories specified by the manufacturer.
  • Page 9: Recommended Usage

    65”: URP65, URP65-T • 75": URP75, URP75-ERO-T • 85": URP85, URP85-ERO-T Planar recommends turning off the power for 4 hours per day for optimal performance. For complete warranty details, please visit http://www.planar.com/warranty. Planar UltraRes P Series User Manual Page | 9 020-1407-01B...
  • Page 10: Important Waste Disposal Information

    It is up to the installer to ensure that display placement is changed, thermal shielding is provided and/or additional ventilation is provided to keep the display within its nominal operating parameters. Maximum ambient operating temperatures for the Planar UltraRes P Series are: •...
  • Page 11: Energy Star Certified

    ENERGY STAR rating. For more information on the ENERGY STAR program, refer to energystar.gov. Planar UltraRes P Series User Manual Page | 11 020-1407-01B...
  • Page 12: Cleaning The Display

    • Do not let cleaner seep into the display, as it may cause electrical shock or damage. • Refer to the Planar Display Cleaning Guidelines for more information. Planar UltraRes P Series User Manual Page | 12 020-1407-01B...
  • Page 13: Unpacking And Checking Accessories

    AC Power adapter for an NEMA 5-15R IEC C14 to US NEMA 5- adapter cable 15R AC cable. (optional) Universal AC Power adapter for an power IEC C14 to EU/UK AC adapter cable. (optional) Planar UltraRes P Series User Manual Page | 13 020-1407-01B...
  • Page 14 Dual-tip stylus. 153mm Stylus (6in) length; 7.5mm and 2mm tips (URP49 / URP55 / URP65 touch models only). Planar® Annotation and TouchMark™ whiteboarding software Single (touch models only). License Key Card Planar UltraRes P Series User Manual Page | 14 020-1407-01B...
  • Page 15 Part Description Number Picture Quick Start Guide: Planar UltraRes X Series, Planar UltraRes P Series, and Planar QE Series Displays Planar UltraRes P Series User Manual Page | 15 020-1407-01B...
  • Page 16: Planar Ultrares P Series - Standard Inputs

    Planar UltraRes P Series – Standard Inputs URP49 / URP49-T URP49 / URP49-T Description SPDIF Audio Out Line Audio Out: 2.5mm TRS (female) IR: 2.5mm TRS (female) PC Audio In: 2.5mm TRS (female) DP 1: 4K/60Hz DP 2: 4K/60Hz HDMI 1: HDMI, 4K/60Hz, HDCP 2.2 HDMI 2: HDMI, 4K/60Hz, HDCP 2.2...
  • Page 17: Urp55 / Urp55-T

    HDMI 3: HDMI, 4K/30Hz, HDCP 1.4 HDMI 4: HDMI, 4K/30Hz, HDCP 1.4 RS232: DB9 (female) USB-A: Service USB-B: Touch AC ON/OFF AC IN: IEC C14 AC OUT Fuse: T3.15L/250V AC OUT: IEC C13 Planar UltraRes P Series User Manual Page | 17 020-1407-01B...
  • Page 18: Urp65 / Urp65-T

    HDMI 3: HDMI, 4K/30Hz, HDCP 1.4 HDMI 4: HDMI, 4K/30Hz, HDCP 1.4 RS232: DB9 (female) USB-A: Service USB-B: Touch AC ON/OFF AC IN: IEC C14 AC OUT Fuse: T3.15L/250V AC OUT: IEC C13 Planar UltraRes P Series User Manual Page | 18 020-1407-01B...
  • Page 19: Urp75 / Urp75-Ero-T

    HDMI Input. HDMI 2: HDMI, 4K/60Hz, HDCP 2.2 HDMI 3: HDMI, 4K/30Hz, HDCP 1.4 HDMI 4: HDMI, 4K/30Hz, HDCP 1.4 DP IN: DisplayPort In, 4K/60Hz DP OUT: DisplayPort Out Planar UltraRes P Series User Manual Page | 19 020-1407-01B...
  • Page 20: Urp85 / Urp85-Ero-T

    HDMI Input. HDMI 2: HDMI, 4K/60Hz, HDCP 2.2 HDMI 3: HDMI, 4K/30Hz, HDCP 1.4 HDMI 4: HDMI, 4K/30Hz, HDCP 1.4 DP IN: DisplayPort In, 4K/60Hz DP OUT: DisplayPort Out Planar UltraRes P Series User Manual Page | 20 020-1407-01B...
  • Page 21: Installing The Display

    • If the display is a touch model, it is important that the touch frame is not used to lift or support the display or touch performance may be compromised. Planar UltraRes P Series User Manual Page | 21 020-1407-01B...
  • Page 22: Prepare Your Installation Location

    4K @ 24/25/30Hz: 15m (50 ft) maximum • 1080p @ 60Hz and lower resolutions: 20m (65 ft) maximum DisplayPort • DP 1.2: 3m (10 ft) maximum • DP 1.1: 5m (15 ft) maximum Planar UltraRes P Series User Manual Page | 22 020-1407-01B...
  • Page 23: Mounting

    The mount must be secured to the Planar UltraRes P Series display using the four M8- 1.25 VESA mounting locations, and 10mm -15mm thread engagement is required for secure mounting.
  • Page 24: Operating The Display

    10.2 URP49 / URP55 / URP65 OSD Keypad Buttons Descriptions Power Power on/Power off Source Source selection (toggle)  Menu Right/Increase value  Menu Left/Decrease value  Menu Up  Menu Down Menu/Exit Menu/Exit Planar UltraRes P Series User Manual Page | 24 020-1407-01B...
  • Page 25: Remote Control Receiver

    The location of the IR remote control receiver is highlighted in the images below. An IR extender cable is included in the accessories package for additional flexibility. URP49 / URP55 / URP65 Planar UltraRes P Series User Manual Page | 25 020-1407-01B...
  • Page 26 URP75 URP85 Planar UltraRes P Series User Manual Page | 26 020-1407-01B...
  • Page 27: Led Indicators

    AC power on Green Flashing (0.5 Hz) Powering on from standby Green Flashing (5 Hz) Firmware updating Amber Flashing (5 Hz) Power supply failure Green and Amber Firmware update failure Planar UltraRes P Series User Manual Page | 27 020-1407-01B...
  • Page 28: Using The Display In Portrait Mode

    Installations where the display is tilted downward or upward at an angle may also be prone to these issues and are not recommended. Note: Failure to follow these instructions will void the warranty. Planar UltraRes P Series User Manual Page | 28 020-1407-01B...
  • Page 29: Using The Remote Control

    15. Using the Remote Control Below are pictures of the remotes. See next section for Hex codes. URP49 / URP55 / URP65 Remote: 952-0088-00 URP75 / URP85 Remote: 952-0086-00 Planar UltraRes P Series User Manual Page | 29 020-1407-01B...
  • Page 30: Ir Command Protocol

    The carrier frequency is 38 kHz, with the modulated pulses having a 33% duty cycle. • Commands are sent at a maximum rate of 9 Hz. For example, below is the NEC control code for the ON button of the Planar UltraRes P Series remote control (assuming the default address is used). Binary...
  • Page 31: Hex Codes (Urp49 / Urp55 / Urp65)

    40AF MENU 0EF1 select the previous submenu.  40AF 03FC Navigates forward through submenus and settings  40AF 19E6 Navigates down through submenus and settings Planar UltraRes P Series User Manual Page | 31 020-1407-01B...
  • Page 32 Allows selection of the different sources 40AF VOLUME - 1BE4 Decreases the sound volume 40AF VOLUME + 1DE2 Increases the sound volume 06F9 01FE Turns the display on 06F9 09F6 Turns the display off Planar UltraRes P Series User Manual Page | 32 020-1407-01B...
  • Page 33 Selects the HDMI 3 input HDMI 4 1785 0x06F92CD3 Selects the HDMI 4 input 1785 0x06F92DD2 Selects the DP 1 input 1785 0x06F92ED1 Selects the DP 2 input 1785 0x06F92FD0 Selects the VGA input Planar UltraRes P Series User Manual Page | 33 020-1407-01B...
  • Page 34: Hex Codes (Urp75 / Urp85)

    Number button 9 1785 0x06F912ED Number button 0 VOL + 1785 0x06F91CE3 Volume increase VOL - 1785 0x06F921DE Volume decrease MUTE 1785 0x06F920DF Audio mute COLOR 1785 0x06F913EC Not used Planar UltraRes P Series User Manual Page | 34 020-1407-01B...
  • Page 35 HDMI 4 1785 0x06F92CD3 Selects HDMI 4 for the current zone 1785 0x06F92DD2 Selects DP for the current zone 1785 0x06F92ED1 Not used 1785 0x06F92FD0 Not used 1785 0x06F930CF Not used Planar UltraRes P Series User Manual Page | 35 020-1407-01B...
  • Page 36: Locking The Keypad And Ir Remote

    RIGHT, LEFT, DOWN. If the keypad is unlocked, you can also unlock the IR remote by using the keypad to go to Main Menu -> Advanced Settings -> System Settings and uncheck IR Remote Lock. Planar UltraRes P Series User Manual Page | 36 020-1407-01B...
  • Page 37: Changing The Ir Remote Code Set

    The IR remote code set transmitted by the remote and accepted by the display can be configured. This is useful if there are multiple Planar displays and you would like each remote to work only with one of the displays. It can also be used if IR interference with another device, such as a DVD player, is occurring.
  • Page 38: Selecting Layouts And Input Sources

    16.10 Selecting Layouts and Input Sources With Planar MediaPlex Plus Processing, you can show one source at a time or multiple sources simultaneously. Multiple layout options are available and can be selected from the Inputs and Views Menu (see page 40). Once a layout has been designated, you can assign sources to each of the zones in the layout.
  • Page 39: Navigating Through The Menus

    To exit the menu system, press EXIT on the remote control, or continue to press MENU/EXIT on the keypad until the main menu is reached. Planar UltraRes P Series User Manual Page | 39 020-1407-01B...
  • Page 40: Inputs And Views Menu

    • Options: HDMI 1, HDMI 2, HDMI 3, HDMI 4, DP, DP2, VGA; Default: HDMI 3 • Note: DP2 and VGA are supported on URP49 / URP55 / URP65 only. Planar UltraRes P Series User Manual Page | 40 020-1407-01B...
  • Page 41 Select from four PiP (Picture-in-Picture) layouts. The layout in orange will be the active layout displayed when the Multi-Source View is set to PiP. PIP Size • Select the size of the PiP (Picture-in-Picture) window. Planar UltraRes P Series User Manual Page | 41 020-1407-01B...
  • Page 42: Image Adjust Menu

    The current zone can be changed via the menu or by using the ZONE 1-4 keys on the remote control. • Note: Changing the Current Zone setting via the ZONE 1-4 keys also changes the Audio Select setting. Planar UltraRes P Series User Manual Page | 42 020-1407-01B...
  • Page 43 Green Gain • Adjust the green gain of the image • Range: 0~200; Default: 100 Blue Gain • Adjust the blue gain of the image • Range: 0~200; Default: 100 Planar UltraRes P Series User Manual Page | 43 020-1407-01B...
  • Page 44 Move the image horizontally or vertically. The amount to move is measured in input pixels. • Range: -1000~1000; Default: 0 Revert to Defaults • Reset all settings in the Image Adjust menu to their factory defaults for the current zone only Planar UltraRes P Series User Manual Page | 44 020-1407-01B...
  • Page 45: Audio Menu

    • Note: This setting applies only to the internal speakers, and cannot be adjusted for the Line Out connector. Balance • Set the audio balance • Range: 0~100; Default: 50 Planar UltraRes P Series User Manual Page | 45 020-1407-01B...
  • Page 46: Presets Menu

    • Range: Preset 1~Preset 10 Save • Save the current setup for later recall • Range: Preset 1~Preset 10 Delete • Delete the selected preset • Range: Preset 1~Preset 10 Planar UltraRes P Series User Manual Page | 46 020-1407-01B...
  • Page 47: Advanced Settings Menu

    17.4 Advanced Settings Menu Panel Brightness Submenu Intensity • Set the intensity of the LCD backlight • Range: 0~100; Default: 75 Planar UltraRes P Series User Manual Page | 47 020-1407-01B...
  • Page 48 • Note: When Wake On Signal is selected, the LAN port and Remote Monitoring web interface will remain accessible after the display enters sleep mode. Planar UltraRes P Series User Manual Page | 48 020-1407-01B...
  • Page 49 Fast Start: The display will enter a standby state with partially reduced power, allowing for 3-5 second wait between an ON command being sent, and image being displayed. IR, Keypad, CEC, LAN, DB9 RS232, and USB communication will remain active. Planar UltraRes P Series User Manual Page | 49 020-1407-01B...
  • Page 50 Note: The specified DNS server is used when Use Network Time is checked for the Set Date and Time setting. DHCP • Turn DHCP on or off • Options: On, Off; Default: On Planar UltraRes P Series User Manual Page | 50 020-1407-01B...
  • Page 51 Chinese (Simplified), Japanese; Default: English OSD Rotation • Rotate the OSD menu so that it is readable if the display is mounted in portrait orientation • Options: Landscape or Portrait; Default: Landscape Planar UltraRes P Series User Manual Page | 51 020-1407-01B...
  • Page 52 • Select the color to display when there is no signal in a zone • Options: Black, White, Gray, Red, Green, Blue, Cyan, Magenta, Yellow • Default: Black Schedule Submenu Planar UltraRes P Series User Manual Page | 52 020-1407-01B...
  • Page 53 Down Mode to Networked Standby Mode or Fast Start. • Data: The preset to recall when the Action is set to Recall, or the backlight setting when the Action is set to Panel Brightness. Planar UltraRes P Series User Manual Page | 53 020-1407-01B...
  • Page 54 1080P selects an EDID format compliant with HDMI 1.3 and DP 1.1 • Options: 4K60, 4K30, 1080P Horizontal Active (URP75 / URP85 only) • The number of active pixels in a line • Range: 0~4095 Planar UltraRes P Series User Manual Page | 54 020-1407-01B...
  • Page 55 The number of line times in the vertical sync • Range: 0~255 Revert to Factory • Reset the EDID type and timings to the default values for the selected connector Planar UltraRes P Series User Manual Page | 55 020-1407-01B...
  • Page 56 Multi-Source View mode and Advanced Layout setting (if applicable). Planar UltraRes P Series User Manual Page | 56 020-1407-01B...
  • Page 57 Cyan x • Adjust the x coordinate of the cyan color point • Range: 0.000-0.800 Cyan y • Adjust the y coordinate of the cyan color point • Range: 0.000-0.800 Planar UltraRes P Series User Manual Page | 57 020-1407-01B...
  • Page 58 Copy the color coordinate settings for the current zone and the current Color Gamut setting to all other zones Revert to Defaults • Reset the color coordinate settings for the current zone and the current Color Gamut setting to their default values Planar UltraRes P Series User Manual Page | 58 020-1407-01B...
  • Page 59 Tiling Submenu (URP75 / URP85 only) This menu contains controls for using multiple Planar UltraRes P Series displays in a tiled configuration. This is useful when trying to display one image across multiple displays. In addition to setting up the width and height of the tiled wall, each display must have its position within the tiled wall properly selected.
  • Page 60 Unit Row 2 Unit Column 3 Unit Column 2 Unit Column 1 Unit Row 1 Unit Row 1 Unit Row 1 Unit Column 3 Unit Column 2 Unit Column 1 Planar UltraRes P Series User Manual Page | 60 020-1407-01B...
  • Page 61 Unit Row 1 Unit Column 3 Unit Column 3 Unit Column 3 Unit Row 3 Unit Row 2 Unit Row 1 Unit Column 4 Unit Column 4 Unit Column 4 Planar UltraRes P Series User Manual Page | 61 020-1407-01B...
  • Page 62 Unit Row 3 Unit Column 2 Unit Column 2 Unit Column 2 Unit Row 1 Unit Row 2 Unit Row 3 Unit Column 1 Unit Column 1 Unit Column 1 Planar UltraRes P Series User Manual Page | 62 020-1407-01B...
  • Page 63 Examples" on page 64. • Options: Disable, Enable; Default: Disable Frame Width, Frame Height • Selects how many lines/pixels are removed from the image to compensate for the display’s bezel Planar UltraRes P Series User Manual Page | 63 020-1407-01B...
  • Page 64 Frame Compensation Examples Below are examples with the Frame Compensation feature enabled (left) and disabled (right). Note that the eagle’s eye is noticeably different when Frame Compensation is disabled. Planar UltraRes P Series User Manual Page | 64 020-1407-01B...
  • Page 65 Test Patterns • Options: Black, Gray, White, Red, Green, Blue, Magenta, Yellow, Cyan, Gray Ramp, Red Ramp, Blue Ramp, Color Bar (URP75 / URP85 only), Checkerboard (URP75 / URP85 only) Planar UltraRes P Series User Manual Page | 65 020-1407-01B...
  • Page 66 System Settings Submenu URP49 / URP55 / URP65 URP75 / URP85 Planar UltraRes P Series User Manual Page | 66 020-1407-01B...
  • Page 67 27. When disabled, the status LEDs are always turned off. • Options: Disable, Enable; Default: Enable Pixel Orbit • Create slight frame motion to help avoid image retention • Options: Enable, Disable; Default: Disable Planar UltraRes P Series User Manual Page | 67 020-1407-01B...
  • Page 68 0x85 Set Stream Path 0x86 Give Device Power Status 0x8F Report Power Status 0x90 Inactive Source 0x9D CEC Version 0x9E Get CEC Version 0x9F Give Features 0xA5 Report Features 0xA6 Planar UltraRes P Series User Manual Page | 68 020-1407-01B...
  • Page 69 Note: The remote that ships with the URP49 / URP55 / URP65 (952-0088-00) only supports the default IR code of 01785. Changing the default IR code requires the use of the 952-0086-00 Planar remote. See “Using the Remote Control” on page 29. •...
  • Page 70 Save All Settings to USB (URP75 / URP85 only) • Save all settings in the display to a USB flash drive. The saved file will be named Planar- settings.bin and will be saved in the root folder of the USB flash drive.
  • Page 71: Information Menu

    17.5 Information Menu System Information Submenu This menu displays version information for all programmable parts in the system. It also contains the model and serial number. Planar UltraRes P Series User Manual Page | 71 020-1407-01B...
  • Page 72 Image Information Submenu This menu displays image details for the current zone. If more than one zone is available, you can change zones by setting the Current Zone option. Planar UltraRes P Series User Manual Page | 72 020-1407-01B...
  • Page 73 Error Log Submenu (URP75 / URP85 only) This menu displays a chronological list of system errors that have occurred. For a list of possible errors, see "Error Codes" on page 116. Planar UltraRes P Series User Manual Page | 73 020-1407-01B...
  • Page 74: Using The Touch Screen

    You can use the touch screen to control your Windows, Mac or Linux operating system. The Planar UltraRes P Series is HID compliant, delivering up to 50 points of touch on URP49 / URP55 / URP65 touch models and up to 20 points of touch on URP75 / URP85 touch models on both Windows and Linux without a driver.
  • Page 75: Planar Ultrares P Series Urp75 / Urp85 Remote Monitoring Software

    URP75 / URP85 Remote Monitoring Software The Planar URP75 and URP85 models feature a web interface that may be accessed from any web browser. This powerful tool is compatible with computers and mobile devices and can be used to control the display and access most of the settings that are available in the On-Screen Menu.
  • Page 76 Typical appearance on a mobile device Planar UltraRes P Series User Manual Page | 76 020-1407-01B...
  • Page 77: Remote Monitoring System Information

    This page displays version information for all programmable parts in the system. It also contains the model and serial number. For the OSD equivalent, refer to "System Settings Submenu" on page 66. Planar UltraRes P Series User Manual Page | 77 020-1407-01B...
  • Page 78: Remote Monitoring Inputs And Views

    This page shows how the sources will be laid out on the screen based on the current Multi- Source View and Advanced Layouts selections. For the OSD equivalent, refer to "Inputs and Views Menu" on page 40. Planar UltraRes P Series User Manual Page | 78 020-1407-01B...
  • Page 79: Remote Monitoring Audio

    This page enables you to make audio adjustments to the selected zone. Note: Volume, Bass, Treble and Balance do not apply to the S/PDIF output. For the OSD equivalent, refer to "Audio Menu" on page 45. Planar UltraRes P Series User Manual Page | 79 020-1407-01B...
  • Page 80: Remote Monitoring Presets

    To save or overwrite a preset, enter the preset number to save or overwrite, optionally enter a custom name for the preset, and then click the Save button. For the OSD equivalent, refer to "Presets Menu" on page 46. Planar UltraRes P Series User Manual Page | 80 020-1407-01B...
  • Page 81: Remote Monitoring Panel Brightness And Power

    This page enables you to make adjustments to the brightness and power settings. For the OSD equivalents, refer to "Panel Brightness Submenu" on page 47 and "Power Submenu" on page 48. Planar UltraRes P Series User Manual Page | 81 020-1407-01B...
  • Page 82: Remote Monitoring Notifications

    Port: Selects the port that the SMTP server uses. • Authentication: Use Auto unless directed by your ISP or network administrator. • User Name: Login username for the SMTP server. Planar UltraRes P Series User Manual Page | 82 020-1407-01B...
  • Page 83 If the test email fails, you can use the View Last 10 Log Messages button to get more detailed information about the failure. Planar UltraRes P Series User Manual Page | 83 020-1407-01B...
  • Page 84: Remote Monitoring System Settings

    26. Remote Monitoring System Settings This page enables you to make adjustments to a variety of system settings. For the OSD equivalent, refer to "System Settings Submenu" on page 66. Planar UltraRes P Series User Manual Page | 84 020-1407-01B...
  • Page 85: Remote Monitoring Access Control

    The default username is Admin. The default password is the serial number, which can be viewed on the System Information tab. Once logged in, all functions can be accessed, and the password for Admin and User can be changed. Planar UltraRes P Series User Manual Page | 85 020-1407-01B...
  • Page 86: Login

    URP49 / URP55 / URP65 Remote Monitoring Software Planar UltraRes P Series Remote Monitoring is a software tool that displays information about the display via a web browser. It is also used to configure email alerts. 28. Login Launch a web browser. Enter the IP address, shown in the Network submenu.
  • Page 87: Information

    29. Information This page displays serial number, model number and firmware version. 30. Network This page allows for network configuration and changing the admin user name and password. Planar UltraRes P Series User Manual Page | 87 020-1407-01B...
  • Page 88: Smtp

    31. SMTP This page allows configuration of SMTP and email alerts. Planar UltraRes P Series User Manual Page | 88 020-1407-01B...
  • Page 89: Snmp

    32. SNMP This page allows configuration of SNMP and Trap. Planar UltraRes P Series User Manual Page | 89 020-1407-01B...
  • Page 90: Control

    33. Control This page allows configuration of the control connection type. Options: Disabled, Telnet, SSH. Default: Telnet Planar UltraRes P Series User Manual Page | 90 020-1407-01B...
  • Page 91: External Control

    External Control In addition to using the Planar UltraRes P Series remote control and display, there are other methods of controlling the Planar UltraRes P Series display externally: • Using a serial link to send ASCII commands and to receive responses to those commands.
  • Page 92: Signal Compatibility

    VESA DMT 1152x864 84.999 77.094 121.500 VESA DMT 1280x768 49.929 39.593 65.250 VESA CVT 1280x768 59.995 47.396 68.250 VESA CVT-R 1280x768 47.776 79.500 VESA CVT 1280x768 74.893 60.289 102.250 VESA CVT Planar UltraRes P Series User Manual Page | 92 020-1407-01B...
  • Page 93 146.250 VESA CVT 1920x2160 135.000 297.000 CEA-861-F, VIC 16, with vertical parameters doubled 2560x1440 59.951 88.787 241.500 VESA CVT-R 2560x1600 59.972 98.713 268.500 VESA CVT-R 3840x2160 52.438 209.750 VESA CVT-R Planar UltraRes P Series User Manual Page | 93 020-1407-01B...
  • Page 94 74.250 SMPTE 274M, CEA-861-F Format 33 1080p 33.750 74.250 SMPTE 274M, CEA-861-F Format 34 1080p 56.250 148.500 SMPTE 274M, CEA-861-F Format 31 1080p 67.500 148.500 SMPTE 274M, CEA-861-F Format 16 Planar UltraRes P Series User Manual Page | 94 020-1407-01B...
  • Page 95 VESA DMT 800x600 46.875 49.5 VESA DMT 800x600 85.061 53.674 56.25 VESA DMT 848x480 59.659 29.83 31.5 VESA CVT 848x480 74.769 37.684 VESA CVT 848x480 84.751 42.969 46.75 VESA CVT Planar UltraRes P Series User Manual Page | 95 020-1407-01B...
  • Page 96 1400x1050 49.965 54.113 VESA CVT 1400x1050 59.948 64.744 VESA CVT-R 1400x1050 59.978 65.317 121.75 VESA CVT 1400x1050 74.867 82.278 VESA CVT 1600x1200 VESA DMT 1920x1080 49.929 55.621 141.5 VESA CVT Planar UltraRes P Series User Manual Page | 96 020-1407-01B...
  • Page 97 ITU-R BT.601, CEA-861-F Formats 21 & EDTV 480p 31.469 ITU-R BT.1358, CEA-861-F Format 17 & 576p 31.25 SMPTE 125M, CEA-861-F Format 6 & 7 HDTV 1080i 28.125 74.5 SMPTE 274M, CEA-861-F Format 20 Planar UltraRes P Series User Manual Page | 97 020-1407-01B...
  • Page 98 3840x2160 112.5 CEA-861-F Format 96 3840x2160 67.5 CEA-861-F Format 97, 4:2:0 sub-sampling 3840x2160 CEA-861-F Format 97 4096x2160 CEA-861-F Format 98 4096x2160 56.25 CEA-861-F Format 99 4096x2160 67.5 CEA-861-F Format 100 Planar UltraRes P Series User Manual Page | 98 020-1407-01B...
  • Page 99: Color Subsampling Report

    YUV 4:2:2 YUV 4:2:0 Video Timing Input Supported Supported Supported Supported 4K @ 50/60 Hz 4K @ 50/60 Hz HDMI 1-2 4K @ 50/60 Hz HDMI 3-4 All Other Supported Timings Planar UltraRes P Series User Manual Page | 99 020-1407-01B...
  • Page 100: Power Consumption

    1.33. The power consumption would increase above these specified values if multi-source views are introduced, and should be taken into account when estimating power consumption. Planar UltraRes P Series User Manual Page | 100 020-1407-01B...
  • Page 101: Specifications

    URP49-T: 44.4" x 25.9" x URP55-T: 49.8" x 28.9" x URP65-T: 58.4" x 33.8" x 2.8" 2.7" 2.8" (1127.2mm x 657.4mm x (1263.8mm x 734.2mm x (1482.7mm x 857.5mm x 69.8mm) 68.8mm) 71.3mm) Planar UltraRes P Series User Manual Page | 101 020-1407-01B...
  • Page 102 ENERGY STAR Certified Touch (-T models only) Surface Treatment Anti-glare (AG) + Anti-fingerprint (AF) Protective Glass 3mm semi-tempered glass Touch Technology Projected Capacitive 50-point, 2mm minimum tip width Touch Interface USB-B Planar UltraRes P Series User Manual Page | 102 020-1407-01B...
  • Page 103 Windows 7, 8, 10, 11; Mac OSX, Linux Passive Pen Item Specification Weight 15g (0.5 oz) Length 153mm (6in) Stylus Tips 2 tips, 2mm and 7mm Tips Active Force 250 ± 50g Planar UltraRes P Series User Manual Page | 103 020-1407-01B...
  • Page 104 DisplayPort 1.2, HDMI 2.0 x 2, HDMI 1.4 x 2 HDCP 2.2 Yes (HDMI 2.0) Audio Output Line out, S/PDIF out LAN RJ45, RS232 In, IR, HDMI CEC, Keypad, Planar® UltraRes™ App Control and Monitoring Mechanical Display Dimensions URP75: 66.3" x 37.9" x 3.6"...
  • Page 105 Min -4°F ~ Max 140°F (-20°C ~ 60°C) Operating Min 32°F ~ Max 104°F (0-40°C) at up to 3000 m Temperature Humidity 20-85% RH Approvals FCC Class A, cTUVus, CE ENERGY STAR Certified Planar UltraRes P Series User Manual Page | 105 020-1407-01B...
  • Page 106: Dimensions

    Dimensions 34. URP49 Planar UltraRes P Series User Manual Page | 106 020-1407-01B...
  • Page 107: Urp49-T

    35. URP49-T Planar UltraRes P Series User Manual Page | 107 020-1407-01B...
  • Page 108: Urp55

    36. URP55 Planar UltraRes P Series User Manual Page | 108 020-1407-01B...
  • Page 109: Urp55-T

    37. URP55-T Planar UltraRes P Series User Manual Page | 109 020-1407-01B...
  • Page 110: Urp65

    38. URP65 Planar UltraRes P Series User Manual Page | 110 020-1407-01B...
  • Page 111: Urp65-T

    39. URP65-T Planar UltraRes P Series User Manual Page | 111 020-1407-01B...
  • Page 112: Urp75

    40. URP75 Planar UltraRes P Series User Manual Page | 112 020-1407-01B...
  • Page 113: Urp75-Ero-T

    41. URP75-ERO-T Planar UltraRes P Series User Manual Page | 113 020-1407-01B...
  • Page 114: Urp85

    42. URP85 Planar UltraRes P Series User Manual Page | 114 020-1407-01B...
  • Page 115: Urp85-Ero-T

    43. URP85-ERO-T Planar UltraRes P Series User Manual Page | 115 020-1407-01B...
  • Page 116: Troubleshooting During Installation

    This section includes troubleshooting information about different issues you may encounter during the installation process or after your display has been running for some time. If you are not able to solve your issue in this section, please contact Planar’s Technical Support team for assistance.
  • Page 117: Symptoms, Possible Causes And Solutions

    45. Symptoms, Possible Causes and Solutions Below are different symptoms that you might encounter as you install your Planar UltraRes P Series display. First look at the different symptoms to see if you can find your issue. And then look at the possible cause and try the suggested solution(s). If you still are not able to resolve your issue, please contact Planar’s Technical Support Department.
  • Page 118: Symptom: Can't Get Pc To Output 4K @ 24/30/60 Hz

    Make sure the IR is fully connected by pressing hard to unsure it is inserted as far as possible. Possible Cause The wired IR module cable is not being used. Solution Make sure that the wired IR module cable is being used. Planar UltraRes P Series User Manual Page | 118 020-1407-01B...
  • Page 119: Symptom: Touch Has Broken Response Near Middle/Bottom Of Display

    Reposition the display so it is vertical to slightly tilted back. Possible Cause There are items blocking the IR sensors from emitting or receiving Solution Clean display and sensor windows around the display. Planar UltraRes P Series User Manual Page | 119 020-1407-01B...
  • Page 120: Accessing Planar's Technical Support Website

    • User Manual • RS232 User Manual • Outline drawings • Standard warranties • Planar support hotline number and email • Firmware (contact Planar support via email or phone) Planar UltraRes P Series User Manual Page | 120 020-1407-01B...

Table of Contents