10
Fireplace Insert Installation

Masonry Fireplace Requirements

CANADA ONLY:
The fireplace insert must be installed with a continuous chimney liner of 6" diameter extending from the
fireplace insert to the top of the chimney. The chimney liner must conform to the Class 3 requirement of
Can/ULC S635, Standard Lining Systems for Existing Masonry or Factory- Built Chimney & Vents, or
CAN/ULC S640, Standard for Lining Systems for New Masonry Chimneys.
Chimney must have a clay tile liner or a stainless steel liner (positive connection).
Entire fireplace, including chimney, must be clean and undamaged. Any damage must be repaired
prior to installation of the insert.
Chimney height: 15' (4.5M) minimum; 33' (10M) maximum.
Entire fireplace, including chimney, must meet local building requirements.
The fireplace insert must be placed on a masonry hearth built to UBC standards.

Zero-Clearance (Metal) Fireplace Requirements

CANADA ONLY:
The fireplace insert must be installed with a continuous chimney liner of 6" diameter extending from the
fireplace insert to the top of the chimney. The chimney liner must conform to the Class 3 requirement of
Can/ULC S635, Standard Lining Systems for Existing Masonry or Factory- Built Chimney & Vents, or
CAN/ULC S640, Standard for Lining Systems for New Masonry Chimneys.
Must utilize a positive (full reline) or direct connection (block-off plate)
Must be manufactured by one of the following manufacturers:
• Marco
• Majestic
• Heat N Glo
Entire fireplace, including chimney, must be clean and undamaged. Any damage must be repaired
prior to installation of the insert
Entire fireplace, including chimney, must meet local building requirements
Chimney height: 15' (4.5M) minimum; 33' (10M) maximum. Minimum cross section: 28.65 square
inches (18626 sq mm)
The damper ("
A
baffles ("
"), screen ("
D
masonry lining ("
frame, face of the fireplace, etc. – "
© Travis Industries
• Heatilator
• Lennox
• Martin
") and grate ("
") must be removed (see Figure 4). The smoke shelf ("
B
"), and metal or glass doors ("
E
"), insulation ("
"), and any structured rigid frame members (metal sides, floor, door
G
H
") may not be removed or altered
I
H
F
E
(for qualified installers only)
• Preway
• Tempco
• Monesson
") may be removed (if applicable). The
F
A
C
I
B
100-01234
• Superior
"), internal
C
D
G
Figure 4