Chimney Requirements

¥
Minimum 15' system height (measured from the floor)
¥
Maximum 35' system height (measured from the floor)
? In some problematic situations, additional chimney height above the specified minimums may be
necessary to reduce wind-induced down drafting and back puffing, or to increase draft, thereby
improving fireplace operating characteristics.

Mantel Requirements

¥
The optional mantel must be non-
combustible
¥
The mantel must be a minimum of 4" below
the header (a maximum 61" above the floor)

Masonry Fireplace Requirements

¥
When required by building codes, vertical
reinforcing rods should be set in the
foundation to extend the full height of the
chimney.
¥
Place insulation along both sides, back, and
top of the Fireplace Xtrordinair to form an
expansion buffer between the fireplace and the
masonry and flue liner.
¥
Allow space to route air duct through masonry. Air duct joints should be screwed securely in place.
¥
When constructed outside of the house framework, chimney anchors should be used.
¥
No chimney should support any structural load besides its own weight.

Facing Requirements

¥
Non-combustible facing must extend 8" from each side of the fireplace
¥
Non-combustible facing must extend 26" from the top of the fireplace
Set-Up Face
¥
The fireplace is shipped with a set-up face that is 1/16" larger on the top, bottom and each side than
the faceplate (arched or square). Use the set-up face as a template when installing the facing.
¥
Arched and square faceplates are available with this fireplace. If using an arched faceplate, remove
the top and two side extenders that are behind the arched set-up face.
I
NSTALLATION
Top square set-up face extension
Side square
set-up face
extension
Arched set-up face
(C
)
ONTINUED
Header
Non-Combustible Mantle
Loosen these screws on each
side to remove the square
set-up face extensions.
4" Min.
Slide the square
set-up face
extensions from
behind the arched
set-up face.