Fireplace Requirements; Insert Placement Requirements; Masonry Fireplace Requirements - Travis Industries 1250 Insert Owner's Manual

Wood insert
Hide thumbs Also See for 1250 Insert:
Table of Contents

Advertisement

8
Stove Installation

Fireplace Requirements

Figure 2 shows the minimum size requirements for the type of fireplace used.
j
i

Insert Placement Requirements

The insert must be placed so that no combustibles are within, or can swing within (e.g. drapes, doors), 36" of the
front of the insert
Insert and hearth must be installed on a level, secure floor
The minimum clearances, facing, and hearth requirements in Figure 3 must be met (follow the clearances for the
type of fireplace being used - either masonry or zero-clearance).
Side
Wall
k
p
q
© Travis Industries
Minimum Fireplace Size
h
b
a
d
c
e
g
f
n
m
l
x
o
100-01233_000
(for qualified installers only)
a
Height (front)
Height (rear)
b
c
Width (front)
Width (rear)
d
e
Depth
f
Hearth Depth*
g
Hearth Width
h
Facing Width
i
Facing Height
j
Mantel Height
* This is the distance the insert protrudes from
the fireplace opening plus the required 16" of
hearth extension in U.S.A. (18" in Canada).
Minimum Clearances
k
Sidewall to Insert
Side Facing
l
m
Top Facing
n
Mantel to Insert
Hearth (Front)*
o
p
Hearth (Side)
q
Front of Insert
x
Extension onto Hearth
* Does not include the distance the insert
extends onto the hearth (dimension "x").
Masonry
Z.C. (Metal)
Fireplace
Fireplace
20-3/4"
20-3/4"
20-3/4"
20-3/4"
23-5/8"
25-5/8"
23-5/8"
25-5/8"
13-1/2"
14-1/2"
19"
19"
39-5/8"
39-5/8"
42-5/8"
47-5/8"
32"
32"
35-1/2"
44"
Figure 2
Masonry
ZC (Metal)
Fireplace
Fireplace
13"
30"
9-1/2"
12"
12"
12"
15-1/2"
24"
16" **
16" ** (** 18" in Canada)
8"
8"
36"
36"
3"
3"
Figure 3
4090819