Monitoring The Chassis; Checking The Overall Chassis Status; Checking The Temperature Status - Alcatel-Lucent OmniSwitch 6450-P10S Hardware User's Manual

Table of Contents

Advertisement

Monitoring the Chassis

Monitoring the Chassis
The OmniSwitch can be monitored and managed via the console port using Command Line Interface
(CLI) commands. The switches can also be monitored and managed via the Ethernet using CLI
commands, WebView, SNMP, and OmniVista.
The section below provides some examples of useful hardware-related monitoring CLI commands. Refer
to the OmniSwitch 6250/6450 CLI Reference Guide for detailed information on all management and
monitoring commands used with the OmniSwitch.

Checking the Overall Chassis Status

To check the overall status of a chassis, including the chassis type, and current administrative and
operational status, use the
-> show chassis
Chassis 1
Model Name:
Description:
Part Number:
Hardware Revision:
Serial Number:
Manufacture Date:
Admin Status:
Operational Status:
Number Of Resets:
MAC Address:
For a complete list of output definitions for this command, refer to the OmniSwitch 6250/6450 CLI
Reference Guide.

Checking the Temperature Status

To check chassis temperature status, including the current temperature and configured threshold values,
use the
show temperature
-> show temperature
Temperature for chassis 1
Hardware Board Temperature (deg C)
Temperature Upper Threshold Range (deg C)
Temperature Upper Threshold (deg C)
Temperature Status
Temperature Danger Threshold (deg C)
For a complete list of output definitions for this command, refer to the OmniSwitch 6250/6450 CLI
Reference Guide.
page 4-4
show chassis
command. For example:
6450 10 PORT COPPER GE,
Virtual Chassis,
903005-90,
03,
M338153P,
AUG 13 2011,
POWER ON,
UP,
4
e8:e7:32:12:e6:6e,
command. For example:
OmniSwitch 6450 Hardware Users Guide
Booting OmniSwitch 6450 Switches
= 54,
= 0 to 85,
= 81,
= UNDER THRESHOLD,
= 85