E2 Fan Error
Checking Fan Electrical Connection
To clear the E2 error code from the controller, please follow these steps:
1. When the barbecue has completed the shutdown procedure and
completely cooled, power off the barbecue and unplug from power
source (A).
2. From the rear of your SMOKEFIRE barbecue, remove the rear access
panel by removing four screws (B).
3. Check the electrical connection to the fan (C). Make sure the
connector is securely joined to the fan's connection point.
4. Reinstall the rear access panel (D).
5. Plug in, power on the barbecue, and begin a cooking session to allow
the controller to run diagnostics.
6. If the E2 error code still remains on the controller, contact the
Customer Service Representative in your area using the contact
information on our website for fan replacement.
TROUBLESHOOTING
A
B
C
D
23