Wiring Color; Electrical Circuit Identification; Waste Outlet And P-Trap - Hussmann Q3SSM10R Installation & Operation Manual

Medium temperature remote cases
Hide thumbs Also See for Q3SSM10R:
Table of Contents

Advertisement

P/N 3068445 _D
Wiring Color Code
Standard Case WireColor Code
Color Decsription
Ground
Anti-Sweat
Lights
Receptacles
T-Stat/Solenoid 230VAC
T-Stat/Solenoid 115VAC
T-Stat/Solenoid 24VAC
Fan Motors
Blue Condensing Unit
Use Copper Conductors Only
430-01-0338 R101003
CASE MUST BE GROUNDED
NOTE: Refer to label affixed to case to determine the
actual configuration as checked in the "TYPE
INSTALLED" boxes.
Electrical Circuit Identification
Standard lighting for all models will be full length fluorescent
lamps located within the case at the top. The switch
controlling the lights, the plug provided for digital scale, and
the thermometer are located at the rear of the case mullion.
The receptacle that is provided on the exterior back of these
models is intended for computerized scales with a five amp
maximum load, not for large motors or other high wattage
appliances. It should be wired to a dedicated circuit.
Electrical Service Receptacles (When Applicable) The
receptacles located on the exterior of the merchandiser are
intended for scales and lighted displays. They are not
intended nor suitable for large motors or other external
appliances.
Color
Green
Purple
Orange
Yellow
Red/Black
White/Black
Red/White
Brown
Field Wiring and Serial Plate Amperage
Field Wiring must be sized for component amperes printed
on the serial plate. Actual ampere draw may be less than
specified. Field wiring from the refrigeration control panel to
the merchandisers is required for refrigeration thermostats.
Case amperes are listed on the wiring diagram, but always
check the serial plate.
LED Driver Location
Drivers are located within the access panel that runs the
length of the rear of the case. Refer to diagram on page 4.
Ashrae Color Code
NOTE: All other manufacturers have no standard sensor
codes.

Waste Outlet and P-TRAP

The waste outlet is located off the center of the case on
one side allowing drip piping to be run lengthwise under
the fixture.
A 1-1/2" P-TRAP and threaded adapter are supplied
with each fixture. The P-TRAP must be installed to
prevent air l eakage and i nsect entrance i nto t he fixture.
NOTE: For installation or maintenance of the P-TRAP,
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 •
DANGER
BEFORE SERVICING
ALWAYS DISCONNECT ELECTRICAL
POWER AT THE MAIN DISCONNECT
WHEN SERVICING OR REPLACING ANY
ELECTRICAL COMPONENT.
This includes (but not limited to) Fans, Heaters
Thermostats, and Lights.
use only adhesive compatible with ABS fittings.
2-2
Item # 18s279
www.hussmann.com