Installing The Waste Drain - Hussmann PMN20F3R Installation Manual

Medium temperature remote cabinet
Table of Contents

Advertisement

INSTALLATION
3.11

INSTALLING THE WASTE DRAIN

1. Install PVC drain parts using recommended PVC
cleaner, primer, and cement per manufacturer's
recommendation.
2. Installed drain piping may require additional
support depending on the number and location
of the hub floor drains. The installer should always
provide adequate support to all drain piping
arrangements to prevent excess stress on all drain
piping components.
3. Ensure the drain trap is assembled correctly as per
Figure 3AG below.
4. Test for leakage and fall by pouring water down the
drain.
5. Ensure trap is primed before starting refrigeration.
FIGURE 3AG- Drain Tap Orientation
Drain waste diameter should be
nominal 40mm standard AS/NZS pipe.
PAGE 25
NOTE:
Drains must be connected to
local council requirements.
Each case must be connected to its
own waste drain. See Figure 3AH
below.
CAUTION:
Incorrectly installed drain
traps could result in adverse air leaking
into the case or the drain becoming
blocked.
No Support
Drain Pipe Stand/Support
FIGURE 3AH- Drain Tap Orientation
PMN20F3R MULTIDECK - HUSSMANN

Advertisement

Table of Contents
loading

Table of Contents