Installing Sensor Probes - Hussmann Multideck Meat 3750 Installation Manual

Table of Contents

Advertisement

Installation manual

Installing Sensor Probes

If required and not already fitted, one sensor probe needs to be installed (supplied by installation contractor) in the ceiling
panel of each case.
To install the probe:
1. Unscrew the plate from the ceiling panel to get access to the conduit for the probe wire. A coloured piece of wire
acting as a draw string is located behind the plate in the conduit
2. Attach the sensor to the back of the plate inside the case.
3. Secure the end of the sensor wire to the draw string wire.
4. On the roof of the case, pull draw wire and sensor wire all the way through the conduit.
5. Seal end of the conduit with putty or silicon
6. Repeat for each case.
________________________________________________________________________________________________________________________
Page 16
Inside case in ceiling
figure 18
CAUTION
Refer to relevant State or Territory legislation
relating to safe working heights.
location of probe
CAUTION
Do not walk or sit on cases.
MJPE multideck and SMD/SME Low Height Multideck
(see figure 18: location of probe)
Outside roof of case
Hussmann