CLEANING & MAINTENANCE
4.3
DAILY CHECKS
•
If an alarm system is not part of the refrigeration
installation, the temperature of each case should
be checked on a daily basis via the thermometer
that may be located in the left hand side of the
ceiling panel, or via another reliable method.
•
The case temperature should be in the range of
-2
C to +4
C (except during defrost).
0
0
•
Up to three separate readings may have to be taken
to ensure the case temperature isn't being taken
during a defrost cycle (which would give a higher
than desired reading).
•
If it is consistently outside this range, contact your
refrigeration service provider.
•
Visually check the case for damage or spills, and
take appropriate remedial action.
•
Visually inspect drain strainer and drain for any
debris which could result in the drains becoming
blocked with the possibility of spilling on the floor
creating a slip hazard.
•
If the cabinet is turned off during non trading hours
ensure the cabinet is cleaned thoroughly to avoid
bacterial growth during off time.
CAUTION:
components are identified during
inspection, isolate case power and
contact service contractor.
CLEANING
A thorough cleaning and service of the case should
be carried out by qualified refrigeration and electrical
engineers on a six monthly basis. Please contact
Hussmann Pty Ltd or your service provider. Cases
should also be cleaned by store staff on at least a weekly
basis; some cases may require more frequent cleaning.
PAGE 34
If any damaged electrical
IMPORTANT NOTES
•
DO NOT use hot water on cold glass surfaces as the
glass may shatter and cause serious injury.
•
DO NOT use abrasive, solvent, ammonia, or oil-
based cleaners.
•
DO NOT use steam or a high-pressure system to
clean the case.
•
When flushing the waste drain, do not use high
pressure water hoses and be careful not to
introduce water faster than the waste outlet/drain
can drain it.
•
DO NOT apply the detergents directly onto the
surfaces to be cleaned.
•
DO NOT use steam cleaning equipment.
•
DO NOT use excessive force.
•
DO NOT use high pressure cleaning equipment.
This may cause injury to the installer or user and
may damage cabinet.
PMM20F3R MULTIDECK - HUSSMANN