    (800) 395-9229 General Instructions THIS BOOKLET CONTAINS INFORMATION ON: RED A narrow depth multi deck air curtain case designed to display pre-packaged Deli products. It can be placed at the end of gondolas or within a gondola by removing a gondola deck and shelves above from one 4'-0"...
  • Page 3: Cut & Plan Views

    Cut & Plan Views " 12" 14" 18" " " 39" Refrigerated Self Sevice End Display Scale = 1/2" 5" 9" Elec. Drain Ref. 1" 1" 72" ( Variable ) Plan View Scale = 1/4" Rev.0309...
  • Page 4: Installation

    IGUP-RED-0309 LOCATION The refrigerated merchandisers have been designed for use only in air conditioned stores where temperature and humidity are maintained at or below 75°F and 55% rela- tive humidity. DO NOT allow air conditioning, electric fans, ovens, open doors or windows (etc.) to create air cur- rents around the merchandiser, as this will impair its cor- rect operation.
  • Page 5: Plumbing

    The water seal should be insulated to prevent condensation. RED (SELF CONTAINED) The waste outlet and P-trap are the same as the remote except the case condensate drains to a pump assembly mounted to the top of the case into the top of the water evap assembly.
  • Page 6: Refrigeration

    IGUP-RED-0309 REFRIGERANT TYPE The standard refrigerant will be R-22 unless otherwise specified on the customer order. Check the serial plate on the case for information. PIPING The refrigerant line outlets are located under the fixture at the left hand end when viewed from the back. Insulate the suction lines to prevent condensation leakage.
  • Page 7: T-Stat Location

    It should be wired to a dedicated circuit. If more than one RED is being installed next to each other, the factory fitted continuous fascia may need to be in- stalled. All fasciae rest on the top of their cases. The self- contained fascia has a hook that needs to be slid through a gusset on the side of the case.
  • Page 8: Case Specifications

    IGUP-RED-0309 Model Refrigeration Average & Btu / Hr. Temperatures (°F) Speed Settings Type Length (Ft.) (Total) Evap. Prod. Disch. 1,700 6,800 20° 34° 1,700 10,200 20° 34° 1,700 13,600 20° 34° 1,700 20,400 20° 34° Set (PSI) 2 Units 2 Units Case Specifications Disch.
  • Page 9: Electrical Schematic

    Rev.0309 Electrical Schematic...
  • Page 10: User Information

    Hussmann cases were not designed to “heat up” or “cool down” product—but rather to maintain an item’s proper temperature for maximum shelf life. To achieve the pro- tection required always: 1.
  • Page 11: Plexiglass & Acrylic Care

    Allow the coating to dry, then bring to a high gloss with a soft cloth. Maintenance COPPER COILS The copper coils used in Hussmann merchandisers may be repaired in the field. Materials are available from local refrigeration wholesalers. Hussmann recommends using #15 Sil-Fos for repairs.
  • Page 12: Appendices

    IGUP-RED-0309 APPENDIX A. – Temperature Guidlines The refrigerators should be operated according to Hussmann’s published engineering specifications for entering air temperatures for specific equipment applications. Table 1 shows the typical temperature of the air entering the food zone one hour before the start of defrost and one hour after defrost for various categories of refrigerators.
  • Page 13: Appendix D. - Recommendations To User

    1.2 Load levels as defined by Hussmann must be observed. 1.3 The best preservation is achieved by following these rules: a) Buy quality products.
  • Page 14 IGUP-RED-0309...
  • Page 15: Limited Warranty

    On Hussmann refrigeration systems, an additional (4) year extended warranty for the motor/compressor assembly is available, but must be purchased prior to shipment to be in effect. Hussmann reserves the right to inspect the job site, installation and reason for failure.
  • Page 16: Hussmann ® Chino 13770 Ramona Avenue • Chino, California

    IGUP-RED-0309 Service Record Last service date: Additional copies of this publication may be obtained by contacting: Hussmann ® Chino 13770 Ramona Avenue • Chino, California 91710 (909) 628-8942 FAX (909) 590-4910 (800) 395-9229 /Chino The MODEL NAME and SERIAL NUMBER is required in order to provide you with the correct parts and information for your particular unit.