Hussmann PMM20F3R Installation Manual page 12

Medium temperature remote cabinet
Table of Contents

Advertisement

PRE INSTALLATION
PACKAGING TAG:
Model No: Identifies the model type (letters on left)
as well as the model size (numbers on right).
Serial Number: The unique number given to each
case.
Asset Code: Optional identification number for
supermarket stores.
Project: Used to identify location site for the case.
SO Number: Sales Order number.
PO Number: Purchasing Order invoice number.
Department
Type:
merchandising location; e.g. bakery, dairy, deli, etc.
ASSET CODE:
Asset Code: Optional identification number for
supermarket stores.
RATING PLATE:
Model: Identifies the model type (letters on left) as
well as the model size (numbers on right).
Climate Class: The climate class relates to the
atmospheric or ambient conditions outside the
fridge or freezer. These conditions determine
how much energy the unit will utilise in specific
environments.
Net Volume: The net volume is the total space
inside the case.
Refrigerant: Identifies the refrigerant used in the
case.
Voltage: Voltage is the amount of potential energy
between two points on a circuit. This is measured
in Volts (V).
Fans Current: The fans flow of electricity which
results from the ordered directional movement of
electrically charged particles, measured in Amps
(A).
PAGE 12
The
type
given
for
RATING PLATE (Continued):
Anti-Sweat Current: The heater that is installed in
the frames and doors of refrigerated cases to reduce
condensation and prevention fogging, measured in
Amps (A).
Defrost and Drain Current: The current from
heaters that are installed in freezer cases to stop the
case from icing up, measured in Amps (A).
Dimensions: The sizing of the case measured in
milimeters (mm) L x W x H.
Type: The type given for merchandising location;
e.g. bakery, dairy, deli, etc.
Net Weight: The net weight is the total weight
including shelving and all part supplied with the
case.
Date of Manufacture: The date of build.
Frequency: Frequency is the rate at which current
changes direction per second. It is measured in
Hertz (Hz), an international unit of measure where 1
Hertz is equal to 1 cycle per second.
Lights Current: The total current of the lighting
modules in a case, measured in Amps (A).
Configuration ID: Identifies the model type, model
size, the lineup number, and the case sequence
number.
Serial Number: The unique number given to each
case.
PMM20F3R MULTIDECK - HUSSMANN