Appendix B
Timing Diagrams
Figure B-12. Sample Clock Timebase Timing Diagram
Selected Start Trigger
Sync Sample Clock Timebase
Time
t
Delay to Selected Start Trigger
18
t
Selected Start Trigger
19
Setup/Hold Time
(to Sync Sample Clock
Timebase)
t
Selected Start Trigger
20
Setup/Hold Time
(to Sync Sample Clock
Timebase)
t
Sync Sample Clock Timebase
21
to SI_Start
B-12 | ni.com
_i
SI Start
Table B-6. Sample Clock Timebase Timing
Description
t
18
t
20
t
19
t
21
Line
PFI
RTSI
STAR
Min (ns)
Max (ns)
3.4
3.3
2.7
1.5
0
0.9
8.8
8.5
5.7
2.2