Time
t
Delay to Selected Start Trigger
13
t
Selected Start Trigger Setup Time
14
(to Sync Convert Clock Timebase)
t
Selected Start Trigger Hold Time
15
(to Sync Convert Clock Timebase)
t
Sync Convert Clock Timebase to
16
Start Trigger
t
Start Trigger to POUT
17
Figure B-11. Sample Clock Timebase Timing and the Analog Input Timing Engine
Selected Reference Trigger
Terminal
_i
Terminal
Terminal
Terminal
Terminal
Table B-5. Convert Clock Timebase Timing
Description
Selected Start Trigger
Selected Pause Trigger
Sample Clock Timebase
Sync Sample Clock Timebase
Convert Clock Timebase
Sync Convert Clock Timebase
Selected Sample Clock
Line
PFI
RTSI
STAR
PFI
RTSI
Reference Trigger
Start Trigger
SI Start
Pause Trigger
SI
Counter
Block
SI_TC
SI2
Counter
Block
Start
M Series User Manual
Min (ns)
3.4
3.3
2.7
1.5
0
0.9
1.1
1.1
SI2_TC
1
© National Instruments | B-11
Max (ns)
8.8
8.5
5.7
2.4
3.1
2.7
Terminal
Terminal
RTSI
Terminal
p_AI_Convert
Terminal

Advertisement

Table of Contents
loading

Table of Contents