Multi-Point Simultaneous Logging - Omron ZS-DSU41 User Manual

Smart sensors data storage unit
Hide thumbs Also See for ZS-DSU41:
Table of Contents

Advertisement

Multi-point Simultaneous Logging

This is an example of how to set to simultaneously log multiple measurement data (e.g.
flatness measurement) at a specific timing.
The following describes an example of how to measurement flatness using the ZS-MDC
and four ZS-LDCs, and perform logging in synchronous with the logging signals of the ZS-
MDC.
Set up logging on the ZS-DSU and ZS-MDC.
Input A
InputB
Sampling start
50ms
ON
Timing signal
to ZS-MDC
OFF
For details on how to connect and install the Sensor Heads and controllers, refer to the "ZS-L Series
User's Manual."
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Multi-point Simultaneous Logging
InputC
Input D
CH0
End
End
Start
Start
Sampling data
Start
Data to be saved in a file
End
Sampling interval
Input A
InputB
InputC
Input D
CH1 CH2 CH3 CH4
CH5
Sampling stop
(Repeat count reached)
Time
End
Start
Logging start trigger
Logging end trigger
Section5
ZS-DSU
5-5
User's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zs-dsu

Table of Contents