Setting the Logging Conditions

Setting the start trigger

Set the conditions for starting logging.
Select one of "SW, EXT, DATA, WINDOW, I/O, HOUR" as the start trigger. When [LOGING]-[TRIG-
GER]-[START] is selected, the first No. that is blinking indicates the current start trigger. The default
value is [SW].
■ BUTTON
This setting item is for inputting the start trigger by key operation on the ZS-DSU. Log-
ging starts when the ↑ UP key is pressed.
FUN Mode-[LOGING]-[TRIGGER]-[START]-[BUTTON]
The UP key is pressed
Logging start
■ EXT INPUT SLOPE
This item is for setting the external input signal as the logging start trigger.
FUN Mode-[LOGGING]-[TRIGGER]-[START]-[EXT]
EDGE
ZS-DSU
3-16
User's Manual
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Setting
Select at which timing, ON or OFF, of the timing signal that logging is to be
started.
Range: OFF→ ON, ON→ OFF (default value: OFF→ ON)
Delays start of logging by about 1.2 ms at most from input of the
external trigger.
Timing input
At OFF
At ON
Description
ON
OFF
1.2ms
ON
Logging start
OFF
1.2ms
Logging start