Section5

Periodic Continuous Logging

Periodic Continuous Logging
In this setting example, data such as measured sheet thickness data is logged periodically
over an extended period of time.
The following describes an example of how to measure the thickness of a sandwiched
sheet by a ZS-MDC and two ZS-LDC and log data over five hours at 100 ms intervals.
Set up logging on the ZS-DSU and ZS-MDC.
For details on how to connect and install the Sensor Heads and controllers, refer to the "ZS-L Series
User's Manual".
ZS-DSU
5-2
User's Manual
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Start
5 hours
100ms
Sampling data
Data to be saved in a file
Sampling interval
Input A
Input B
CH0
CH1
End
Start
Logging start trigger
End
Logging end trigger
Input A Input B
CH2
CH3
Time